ADEA71A2VEB / AZAS71M2V1B (Archived) ADEA100A2VEB / AZAS100M7V1B (Archived) ADEA125A2VEB / AZAS125M7V1B (Archived)
Indoor unit ADEA71A2VEB ADEA100A2VEB ADEA125A2VEB
Outdoor unit AZAS71M2V1B AZAS100M7V1B AZAS125M7V1B
Cooling capacity Nom. kW 6.80 9.50 12.10
  Nom. Btu/h 23,200 32,400 41,300
  Nom. kcal/h 5,847 8,169 10,404
Heating capacity Nom. kW 7.50 10.80 13.50
  Nom. Btu/h 25,600 36,900 46,100
  Nom. kcal/h 6,449 9,286 11,608
Power input Cooling Nom. kW 2.08 2.97 5.33
  Heating Nom. kW 2.07 2.33 3.47
Nominal efficiency EER   3.27 3.20 2.27
  COP   3.62 4.63 3.89
Space cooling Energy efficiency class   A A  
  Capacity Pdesign kW 6.80 9.50 12.10
  SEER   5.44 5.13 4.73
  ηs,c %     186
  Annual energy consumption kWh/a 437 648 1,534
  A Condition (35°C - 27/19) Pdc kW 6.80 9.50 12.10
    EERd   3.27 3.20 2.27
    Power input kW 2.08 2.97 5.33
  B Condition (30°C - 27/19) Pdc kW 5.02 7.00 8.92
    EERd   4.59 4.42 3.72
    Power input kW 1.09 1.58 2.40
  C Condition (25°C - 27/19) Pdc kW 3.23 4.50 5.74
    EERd   6.79 6.03 5.46
    Power input kW 0.48 0.75 1.05
  D Condition (20°C - 27/19) Pdc kW 2.92 3.10 3.17
    EERd   8.56 7.39 7.49
    Power input kW 0.34 0.42 0.42
Space heating (Average climate) Energy efficiency class   A A  
  Capacity Pdesign kW 4.50 6.00 6.00
  SCOP/A   3.81 3.81 3.50
  SCOPnet/A   3.81 3.81 3.50
  ηs,h %     137
  Pdh Heating capacity at -10° kW 4.50 6.00 6.00
  Annual energy consumption kWh/a 1,654 2,206 2,399
  Required back up heating cap at design conditions kW 0.00 0.00 0.00
  TOL Tol (temperature operating limit) °C -10 -10 -10
    Pdh (declared heating cap) kW 4.50 6.00 6.00
    COPd (declared COP)   2.26 2.42 2.45
    Power input kW 1.99 2.48 2.45
  TBivalent Tbiv (bivalent temperature) °C -10 -10 -10
    Pdh (declared heating cap) kW 4.50 6.00 6.00
    COPd (declared COP)   2.26 2.42 2.45
    Power input kW 1.99 2.48 2.45
  A Condition (-7°C) Pdh (declared heating cap) kW 3.98 5.31 5.30
    COPd (declared COP)   2.53 2.66 2.66
    Power input kW 1.57 2.00 1.99
  B Condition (2°C) Pdh (declared heating cap) kW 2.42 3.23 3.23
    COPd (declared COP)   3.91 3.73 3.45
    Power input kW 0.62 0.87 0.94
  C Condition (7°C) Pdh (declared heating cap) kW 2.06 2.26 2.27
    COPd (declared COP)   4.79 4.78 4.11
    Power input kW 0.43 0.47 0.55
  D Condition (12°C) Pdh (declared heating cap) kW 2.43 2.57 2.66
    COPd (declared COP)   5.88 5.64 5.03
    Power input kW 0.41 0.46 0.53
Power consumption in other than active mode Crankcase heater mode Cooling PCK kW 0.000 0.000 0.000
    Heating PCK kW 0.000 0.000 0.000
  Off mode Cooling POFF kW 0.014 0.014 0.014
    Heating POFF kW 0.014 0.014 0.014
  Standby mode Cooling PSB kW 0.014 0.014 0.014
    Heating PSB kW 0.014 0.014 0.014
  Thermostat-off mode Cooling PTO kW 0.000 0.000 0.000
    Heating PTO kW 0.014 0.014 0.014
Indication if the heater is equipped with a supplementary heater (pair application)     No
Cooling Cdc (Degradation cooling)   0.25 0.25 0.25
Heating Cdh (Degradation heating)   0.25 0.25 0.25
Cooling function included Yes Yes Yes
Heating function included Yes Yes Yes
Average climate included Yes Yes Yes
Cold season included No No No
Warm season included No No No
Notes (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range
  (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data
  (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.