Specifications Table for ATXF-A / ARXF-A

ATXF20A5V1B / ARXF20A5V1B ATXF25A5V1B / ARXF25A5V1B ATXF35A5V1B / ARXF35A5V1B ATXF50A2V1B / ARXF50A2V1B ATXF60A2V1B / ARXF60A2V1B ATXF71A2V1B / ARXF71A2V1B
Cooling capacity Min. kW 1.3 1.3 1.3 1.70 1.70 2.30
  Nom. kW 2.00 2.50 3.30 5.00 6.00 7.10
  Max. kW 2.6 3.0 3.8 6.00 7.00 7.30
Heating capacity Min. kW 1.30 1.30 1.30 1.70 1.70 2.30
  Nom. kW 2.50 2.80 3.50 6.00 6.40 8.20
  Max. kW 3.50 4.00 4.80 7.70 8.00 9.00
Nominal efficiency EER   3.91 3.27 3.27 3.30 3.25 2.53
  COP   4.16 3.98 3.98 3.71 3.90 3.12
  Annual energy consumption kWh       758 923 1,403
  Energy labeling Directive Cooling   A A A A A E
    Heating   A A A A A D
Space cooling Capacity Pdesign kW 2.00 2.50 3.50 5.00 6.00 7.10
  Energy efficiency class   A++ A++ A++ A++ A++ A
  SEER   6.12 6.19 6.18 6.18 6.12 5.12
  Annual energy consumption kWh/a 114 141 198 283 343 486
Space heating (Average climate) Capacity Pdesign kW 2.20 2.40 2.80 4.60 4.80 6.20
  Energy efficiency class   A+ A+ A+ A+ A+ A
  SCOP/A   4.07 4.03 4.03 4.03 4.03 3.81
  Annual energy consumption kWh/a 756 831 972 1,598 1,670 2,278
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.      
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.      
  (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data