Specifications Table for EABH-D9W / EPGA011-016DV

EABH16DA9W / EPGA11DAV3 EABH16DA9W / EPGA14DAV3 EABH16DA9W / EPGA16DAV3
Indoor unit EABH16DA9W EABH16DA9W EABH16DA9W
Outdoor unit EPGA11DAV3 EPGA14DAV3 EPGA16DAV3
Heating capacity Nom. kW 11.1 (1), 11.3 (2) 14.5 (1), 14.5 (2) 16.5 (1), 15.6 (2)
Power input Heating Nom. kW 2.16 (1), 2.91 (2) 2.91 (1), 3.96 (2) 3.45 (1), 4.21 (2)
COP 5.15 (1), 3.88 (2) 4.99 (1), 3.65 (2) 4.78 (1), 3.71 (2)
Pump Type   Grundfos UPMXL GEO 25-125 130 PWM Grundfos UPMXL GEO 25-125 130 PWM Grundfos UPMXL GEO 25-125 130 PWM
  Nominal ESP unit Heating kPa 83.1 (1), 83.4 (2) 57.5 (1), 56.3 (2) 43.8 (1), 45.2 (2)
Water side Heat exchanger Water flow rate Heating Nom. l/min 32.5 (1), 32.4 (2) 41.2 (1), 41.5 (2) 45.1 (1), 44.7 (2)
General Supplier/Manufacturer details Name and address   Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
    Name or trademark   Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V.
  Product description Air-to-water heat pump   Yes Yes Yes
    Brine-to-water heat pump   No No No
    Heat pump combination heater   No No No
    Low-temperature heat pump   No No No
    Supplementary heater integrated   Yes Yes Yes
    Water-to-water heat pump   No No No
  LW(A) Sound power level (according to EN14825) Indoor dB(A) 44.0 44.0 44.0
LW(A) Sound power level (according to EN14825) Outdoor dB(A) 64.0 64.0 66.0
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825 Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825 Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825
Space heating general Air to water unit Rated airflow (outdoor) m³/h 6,900 6,900 8,100
  Other Capacity control   Inverter Inverter Inverter
    Pck (Crankcase heater mode) kW 0.000 0.000 0.000
    Poff (Off mode) kW 0.021 0.021 0.021
    Psb (Standby mode) kW 0.021 0.021 0.021
    Pto (Thermostat off) kW 0.041 0.041 0.041
  Integrated supplementary heater Psup kW 9.0 9.0 9.0
    Type of energy input   Electrical Electrical Electrical
Space heating Average climate water outlet 55°C General Annual energy consumption kWh 7,845 8,669 9,706
      Ƞs (Seasonal space heating efficiency) % 129 130 133
      Prated at -10°C kW 13 14 16
      Qhe Annual energy consumption (GCV) Gj 28.2 31.2 34.9
      SCOP   3.29 3.34 3.41
      Seasonal space heating eff. class   A++ A++ A++
    A Condition (-7°CDB/-8°CWB) Cdh (Degradation heating)   1.0 1.0 1.0
      COPd   2.25 2.17 2.23
      Pdh kW 11.5 12.3 13.1
      PERd % 90.0 86.8 89.2
    B Condition (2°CDB/1°CWB) Cdh (Degradation heating)   1.0 1.0 1.0
      COPd   3.14 3.18 3.26
      Pdh kW 6.5 8.1 8.7
      PERd % 125.6 127.2 130.4
    C Condition (7°CDB/6°CWB) Cdh (Degradation heating)   0.96 1.0 1.0
      COPd   4.27 4.46 4.62
      Pdh kW 4.6 5.0 5.8
      PERd % 170.8 178.4 184.8
    D Condition (12°CDB/11°CWB) Cdh (Degradation heating)   0.95 0.95 0.95
      COPd   5.75 5.94 6.47
      Pdh kW 5.2 5.2 5.2
      PERd % 230.0 237.6 258.8
    Tol (temperature operating limit) COPd   2.11 2.10 2.05
      Pdh kW 12.5 13.5 13.2
      PERd % 84.4 84.0 82.0
      TOL °C -10 -10 -10
      WTOL °C 55 55 55
    Rated heat output supplementary capacity Psup (at Tdesign -10°C) kW 0.0 0.5 2.8
    Tbiv (bivalent temperature) COPd   2.11 2.17 2.40
      Pdh kW 12.5 12.3 12.9
      PERd % 84.4 86.8 96.0
      Tbiv °C -10 -7 -5
  Cold climate water outlet 55°C General Annual energy consumption kWh 10,085 11,385 12,295
      Ƞs (Seasonal space heating efficiency) % 124 123 121
      Prated at -22°C kW 13 15 15
      Qhe Annual energy consumption (GCV) Gj 36.3 41.0 44.3
    A Condition (-7°CDB/-8°CWB) Cdh (Degradation heating)   1.0 1.0 1.0
      COPd   2.68 2.61 2.58
      Pdh kW 8.3 8.8 9.4
      PERd % 107.2 104.4 103.2
    B Condition (2°CDB/1°CWB) Cdh (Degradation heating)   1.0 1.0 1.0
      COPd   3.75 3.75 3.66
      Pdh kW 5.1 5.5 5.9
      PERd % 150.0 150.0 146.4
    C Condition (7°CDB/6°CWB) Cdh (Degradation heating)   0.96 0.96 0.96
      COPd   4.63 4.70 4.75
      Pdh kW 4.5 4.5 4.5
      PERd % 185.2 188.0 190.0
    D Condition (12°CDB/11°CWB) COPd   6.01 6.13 6.21
      Pdh kW 5.2 5.2 5.1
      PERd % 240.4 245.2 248.4
    Tol (temperature operating limit) COPd   1.34 1.34 1.34
      Pdh kW 7.5 7.5 7.5
      PERd % 53.6 53.6 53.6
      TOL °C -21 -21 -21
      WTOL °C 54 54 54
    G Condition (-15°CDB/-) COPd   2.10 2.12 2.13
      Pdh kW 11.1 11.9 12.6
      PERd % 84.0 84.8 85.2
    Tbiv (bivalent temperature) COPd   1.93 2.05 2.13
      Pdh kW 11.4 12.4 12.6
      PERd % 77.2 82.0 85.2
      Tbiv °C -18 -16 -15
    Rated heat output supplementary capacity Psup (at Tdesign -22°C) kW 5.5 7.0 7.9
  Warm climate water outlet 55°C General Annual energy consumption kWh 3,696 4,104 4,362
      Ƞs (Seasonal space heating efficiency) % 156 160 162
      Prated at 2°C kW 11 13 14
      Qhe Annual energy consumption (GCV) Gj 13.3 14.8 15.7
    B Condition (2°CDB/1°CWB) Cdh (Degradation heating)   1.0 1.0 1.0
      COPd   2.45 2.43 2.41
      Pdh kW 11.4 12.4 13.5
      PERd % 98.0 97.2 96.4
    C Condition (7°CDB/6°CWB) Cdh (Degradation heating)   1.0 1.0 1.0
      COPd   3.58 3.62 3.66
      Pdh kW 7.2 7.9 8.7
      PERd % 143.2 144.8 146.4
    D Condition (12°CDB/11°CWB) Cdh (Degradation heating)   0.96 0.96 0.96
      COPd   5.16 5.29 5.38
      Pdh kW 5.3 5.2 5.2
      PERd % 206.4 211.6 215.2
    Tbiv (bivalent temperature) COPd   2.45 2.43 2.41
      Pdh kW 11.4 12.4 13.5
      PERd % 98.0 97.2 96.4
      Tbiv °C 2 2 2
  Average climate water outlet 35°C General SCOP   4.38 4.45 4.56
      Annual energy consumption kWh 5,189 5,797 6,345
      Ƞs (Seasonal space heating efficiency) % 172 175 179
      Prated at -10°C kW 11 13 14
      Qhe Annual energy consumption (GCV) Gj 18.7 20.9 22.8
      Seasonal space heating eff. class   A++ A+++ A+++
    A Condition (-7°CDB/-8°CWB) COPd   3.07 2.85 2.99
      Pdh kW 9.7 11.1 12.2
      PERd % 122.8 114.0 119.6
    B Condition (2°CDB/1°CWB) Cdh (Degradation heating)   1.0 1.0 1.0
      COPd   4.15 4.24 4.30
      Pdh kW 6.3 7.0 7.4
      PERd % 166.0 169.6 172.0
    C Condition (7°CDB/6°CWB) Cdh (Degradation heating)   0.95 1.0 0.95
      COPd   5.86 6.24 6.35
      Pdh kW 4.5 4.5 5.0
      PERd % 234.4 249.6 254.0
    D Condition (12°CDB/11°CWB) Cdh (Degradation heating)   0.94 0.94 0.94
      COPd   7.88 8.12 8.12
      Pdh kW 5.3 5.3 5.3
      PERd % 315.2 324.8 324.8
    Tol (temperature operating limit) COPd   2.80 2.53 2.72
      Pdh kW 11.0 12.5 14.5
      PERd % 112.0 101.2 108.8
      TOL °C -10 -10 -10
      WTOL °C 35 35 35
    Tbiv (bivalent temperature) COPd   2.80 2.53 2.72
      Pdh kW 11.0 12.5 14.5
      PERd % 112.0 101.2 108.8
      Tbiv °C -10 -10 -10
    Rated heat output supplementary capacity Psup (at Tdesign -10°C) kW 0.0 0.0 0.0
  Cold climate water outlet 35°C General Annual energy consumption kWh 9,295 10,249 11,108
      Ƞs (Seasonal space heating efficiency) % 151 151 157
      Prated at -22°C kW 15 16 18
      Qhe Annual energy consumption (GCV) Gj 33.5 36.9 40.0
    A Condition (-7°CDB/-8°CWB) COPd   3.09 3.20 3.39
      Pdh kW 9.0 9.7 10.8
      PERd % 123.6 128.0 135.6
    B Condition (2°CDB/1°CWB) Cdh (Degradation heating)   1.0 1.0 0.97
      COPd   4.45 4.45 4.68
      Pdh kW 5.6 5.6 7.1
      PERd % 178.0 178.0 187.2
    C Condition (7°CDB/6°CWB) Cdh (Degradation heating)   0.94 0.94 0.94
      COPd   6.24 6.46 6.75
      Pdh kW 4.5 4.5 4.6
      PERd % 249.6 258.4 270.0
    D Condition (12°CDB/11°CWB) Cdh (Degradation heating)   0.94 0.94 0.94
      COPd   7.84 7.98 8.19
      Pdh kW 5.2 5.3 5.3
      PERd % 313.6 319.2 327.6
    Tol (temperature operating limit) COPd   2.13 2.10 2.10
      Pdh kW 11.8 13.5 13.5
      PERd % 85.2 84.0 84.0
      TOL °C -22 -22 -22
      WTOL °C 35 35 35
    G Condition (-15°CDB/-) COPd   2.67 2.43 2.40
      Pdh kW 12.1 13.4 14.6
      PERd % 106.8 97.2 96.0
    Tbiv (bivalent temperature) COPd   2.49 2.36 2.40
      Pdh kW 13.1 13.7 14.6
      PERd % 99.6 94.4 96.0
      Tbiv °C -18 -16 -15
    Rated heat output supplementary capacity Psup (at Tdesign -22°C) kW 2.7 2.5 4.5
  Warm climate water outlet 35°C General Annual energy consumption kWh 2,496 2,779 3,136
      Ƞs (Seasonal space heating efficiency) % 233 237 236
      Prated at 2°C kW 11 13 14
      Qhe Annual energy consumption (GCV) Gj 8.99 10.0 11.3
    B Condition (2°CDB/1°CWB) Cdh (Degradation heating)   1.0 1.0 1.0
      COPd   3.40 3.25 3.22
      Pdh kW 11.1 12.4 12.7
      PERd % 136.0 130.0 128.8
    C Condition (7°CDB/6°CWB) Cdh (Degradation heating)   1.0 1.0 1.0
      COPd   5.67 5.70 5.73
      Pdh kW 7.6 8.4 9.3
      PERd % 226.8 228.0 229.2
    Tbiv (bivalent temperature) COPd   3.40 3.25 3.44
      Pdh kW 11.1 12.4 12.2
      PERd % 136.0 130.0 137.6
      Tbiv °C 2 2 4
    D Condition (12°CDB/11°CWB) Cdh (Degradation heating)   0.94 0.94 0.94
      COPd   7.60 7.78 8.03
      Pdh kW 5.2 5.3 5.3
      PERd % 304.0 311.2 321.2
Notes (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )