Specifications Table for EGSQH-A9W

EGSQH10S18AA9W
Heating capacity Min. kW 3.11 (1), 2.47 (2)
  Nom. kW 10.2 (1), 9.29 (2)
  Max. kW 13.0 (1), 11.9 (2)
Power input Nom. kW 2.34 (1), 2.82 (2)
COP 4.35 (1), 3.29 (2)
Casing Colour   White
  Material   Precoated sheet metal
Dimensions Unit Height mm 1,730
    Width mm 600
    Depth mm 728
Weight Unit kg 210
Tank Water volume l 180
  Insulation Heat loss kWh/24h 1.36 (4)
  Corrosion protection   Anode
Refrigerant Type   R-410A
  GWP   2,090
  Charge TCO2Eq 3.76
  Charge kg 1.80
Sound power level Nom. dBA 46.0
Sound pressure level Nom. dBA 32.0 (6)
Operation range Installation space Min. °C 5.00
    Max. °C 30.0
  Brine side Min. °C -5.00
    Max. °C 20.0
  Heating Water side Min. °C 24 (7), 24 (8)
      Max. °C 60.0 (7), 65.0 (8)
  Domestic hot water Water side Min. °C 25 (7), 25 (9)
      Max. °C 55 (7), 60 (9)
Space heating Average climate water outlet 55°C General SCOP   3.79
      Seasonal space heating eff. class   A++
  Average climate water outlet 35°C General SCOP   5.26
      Seasonal space heating eff. class   A+++
Power supply Name   9W
  Phase   3~
  Frequency Hz 50
  Voltage V 400
Current Recommended fuses A 25
Notes (1) - EWB/LWB 0°C/-3°C - LWC 35°C (DT=5°C)
  (2) - EWB/LWB 0°C/-3°C - LWC 45°C (DT=5°C)
  (3) - with 40% propylene glycol
  (4) - Heatloss according to EN12897
  (5) - Including piping + PHE + back-up heater; excluding expansion vessel
  (6) - The sound pressure level is measured via a microphone at a 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.
  (7) - By heat pump
  (8) - By heat pump + back-up heater
  (9) - By back-up heater