EHSX04P50DA / ERGA04DAV3 EHSX04P30DA / ERGA04DAV3 EHSX08P30DA / ERGA06DAV3 EHSX08P50DA / ERGA06DAV3 EHSX08P50DA / ERGA08DAV3A EHSX08P30DA / ERGA08DAV3A EHSX08P30DA / ERGA08DAV3 EHSX08P50DA / ERGA08DAV3
Indoor unit EHSX04P50D EHSX04P30D EHSX08P30D EHSX08P50D EHSX08P50D EHSX08P30D EHSX08P30D EHSX08P50D
Outdoor unit ERGA04DAV3 ERGA04DAV3 ERGA06DAV3 ERGA06DAV3 ERGA08DAV3A ERGA08DAV3A ERGA08DAV3 ERGA08DAV3
Heating capacity Nom. kW 4.30 (1), 4.60 (2) 4.30 (1), 4.60 (2) 6.00 (1), 5.90 (2) 6.00 (1), 5.90 (2) 7.50 (1), 7.80 (2) 7.50 (1), 7.80 (2) 7.50 (1), 7.80 (2) 7.50 (1), 7.80 (2)
Cooling capacity Nom. kW 5.56 (1), 4.37 (2) 5.56 (1), 4.37 (2) 5.96 (1), 4.87 (2) 5.96 (1), 4.87 (2) 5.35 (2), 6.25 (1) 5.35 (2), 6.25 (1) 6.25 (1), 5.35 (2) 6.25 (1), 5.35 (2)
Power input Heating Nom. kW 0.850 (1), 1.26 (2) 0.850 (1), 1.26 (2) 1.24 (1), 1.69 (2) 1.24 (1), 1.69 (2) 1.63 (1), 2.23 (2) 1.63 (1), 2.23 (2) 1.63 (1), 2.23 (2) 1.63 (1), 2.23 (2)
  Cooling Nom. kW 0.940 (1), 1.14 (2) 0.940 (1), 1.14 (2) 1.06 (1), 1.33 (2) 1.06 (1), 1.33 (2) 1.16 (1), 1.51 (2) 1.16 (1), 1.51 (2) 1.16 (1), 1.51 (2) 1.16 (1), 1.51 (2)
Heat up time from 10°C to 50°C hr 2h57min 1h31min 1h31min 2h57min     1h31min 2h57min
COP 5.10 (1), 3.65 (2) 5.10 (1), 3.65 (2) 4.85 (1), 3.50 (2) 4.85 (1), 3.50 (2) 3.50 (2), 4.60 (1) 3.50 (2), 4.60 (1) 4.60 (1), 3.50 (2) 4.60 (1), 3.50 (2)
EER 5.94 (1), 3.84 (2) 5.94 (1), 3.84 (2) 5.61 (1), 3.67 (2) 5.61 (1), 3.67 (2) 3.54 (2), 5.40 (1) 3.54 (2), 5.40 (1) 5.40 (1), 3.54 (2) 5.40 (1), 3.54 (2)
Pump Type   Grundfos UPM3K 25-75 CHBL Grundfos UPM3K 25-75 CHBL Grundfos UPM3K 25-75 CHBL Grundfos UPM3K 25-75 CHBL     Grundfos UPM3K 25-75 CHBL Grundfos UPM3K 25-75 CHBL
  Nominal ESP unit Cooling kPa 60.5 (1), 65.8 (2) 60.5 (1), 65.8 (2) 57.6 (1), 63.9 (2) 57.6 (1), 63.9 (2) 55.5 (1), 61.7 (2) 55.5 (1), 61.7 (2) 55.5 (1), 61.7 (2) 55.5 (1), 61.7 (2)
    Heating kPa 66.0 (1), 65.0 (2) 66.0 (1), 65.0 (2) 57.4 (1), 58.1 (2) 57.4 (1), 58.1 (2) 38.7 (2), 42.7 (1) 38.7 (2), 42.7 (1) 42.7 (1), 38.7 (2) 42.7 (1), 38.7 (2)
Water side Heat exchanger Water flow rate Cooling Nom. l/min 15.9 (1), 12.5 (2) 15.9 (1), 12.5 (2) 17.1 (1), 14.0 (2) 17.1 (1), 14.0 (2) 15.3 (2), 17.9 (1) 15.3 (2), 17.9 (1) 17.9 (1), 15.3 (2) 17.9 (1), 15.3 (2)
    Heating Nom. l/min 12.3 (1), 13.2 (2) 12.3 (1), 13.2 (2) 17.2 (1), 16.9 (2) 17.2 (1), 16.9 (2) 21.5 (1), 22.4 (2) 21.5 (1), 22.4 (2) 21.5 (1), 22.4 (2) 21.5 (1), 22.4 (2)
General Product description Air-to-water heat pump   Yes Yes Yes Yes Yes Yes Yes Yes
    Brine-to-water heat pump   No No No No No No No No
    Heat pump combination heater   Yes Yes Yes Yes Yes Yes Yes Yes
    Low-temperature heat pump   No No No No No No No No
    Supplementary heater integrated   No No No No No No No No
    Water-to-water heat pump   No No No No No No No No
  LW(A) Sound power level (according to EN14825) Indoor dB(A) 39 39 39 39 39 39 39 39
LW(A) Sound power level (according to EN14825) Outdoor dB(A) 58 58 60 60 62 62 62 62
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825 Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825 Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825 Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825 Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825 Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825 Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825 Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825
Space heating general Air to water unit Rated airflow (outdoor) m³/h 2,280 2,280 2,520 2,520 2,770 2,770 2,770 2,770
  Other Capacity control   Inverter Inverter Inverter Inverter Inverter Inverter Inverter Inverter
    Poff (Off mode) kW 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010
    Psb (Standby mode) kW 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010
    Pto (Thermostat off) kW 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010
  Integrated supplementary heater Type of energy input   Electrical Electrical Electrical Electrical Electrical Electrical Electrical Electrical
Domestic hot water heating General Declared load profile   XL L L XL XL L L XL
    Function to fix water heating during off peak hours   Yes Yes Yes Yes Yes Yes Yes Yes
  Average climate AEC (Annual electricity consumption) kWh 1,584 951 951 1,584 1,715 1,074 951 1,584
    Ƞwh (water heating efficiency) % 106 108 108 106 98 95 108 106
    Qelec (Daily electricity consumption) kWh 7.426 4.500 4.500 7.426 8.037 5.128 4.500 7.426
    Water heating energy efficiency class   A A A A   A A A
  Cold climate AEC (Annual electricity consumption) kWh 2,260 1,366 1,366 2,260 2,260 1,366 1,366 2,260
    Ƞwh (water heating efficiency) % 75 75 75 75 75 75 75 75
    Qelec (Daily electricity consumption) kWh 10.520 6.454 6.454 10.520 10.520 6.454 6.454 10.520
  Warm climate AEC (Annual electricity consumption) kWh 1,436 940 940 1,436 1,436 940 940 1,436
    Ƞwh (water heating efficiency) % 117 109 109 117 117 109 109 117
    Qelec (Daily electricity consumption) kWh 6.766 4.513 4.513 6.766 6.766 4.513 4.513 6.766
Space heating Average climate water outlet 55°C General SCOP   3.26 3.26 3.26 3.26 3.27 3.27 3.32 3.32
      Annual energy consumption kWh 3,806 3,806 4,441 4,441 4,731 4,731 4,975 4,975
      Ƞs (Seasonal space heating efficiency) % 127 127 127 127 128 128 130 130
      Prated at -10°C kW 6.0 6.0 7.0 7.0 8 8 8.0 8.0
      Seasonal space heating eff. class   A++ A++ A++ A++ A++ A++ A++ A++
    A Condition (-7°CDB/-8°CWB) Cdh (Degradation heating)   1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
      COPd   1.97 1.97 1.98 1.98 198.00 198.00 1.96 1.96
      Pdh kW 5.3 5.3 5.9 5.9 5.9 5.9 6.9 6.9
      PERd % 79.0 79.0 79.0 79.0 79.0 79.0 78.0 78.0
    B Condition (2°CDB/1°CWB) Cdh (Degradation heating)   1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
      COPd   3.23 3.23 3.16 3.16 3.18 3.18 3.20 3.20
      Pdh kW 3.3 3.3 3.9 3.9 4.1 4.1 4.4 4.4
      PERd % 129.0 129.0 126.0 126.0 127.0 127.0 128.0 128.0
    C Condition (7°CDB/6°CWB) Cdh (Degradation heating)   1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
      COPd   4.40 4.40 4.49 4.49 4.54 4.54 4.64 4.64
      Pdh kW 3.0 3.0 3.0 3.0 3.0 3.0 3.3 3.3
      PERd % 176.0 176.0 180.0 180.0 182.0 182.0 186.0 186.0
    D Condition (12°CDB/11°CWB) Cdh (Degradation heating)   1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
      COPd   6.10 6.10 6.10 6.10 6.16 6.16 6.22 6.22
      Pdh kW 3.3 3.3 3.3 3.3 3.7 3.7 4.1 4.1
      PERd % 244.0 244.0 244.0 244.0 246.0 246.0 249.0 249.0
    Tol (temperature operating limit) COPd   1.37 1.37 1.53 1.53 1.43 1.43 1.64 1.64
      Pdh kW 4.0 4.0 5.4 5.4 4.5 4.5 7.1 7.1
      PERd % 55.0 55.0 61.0 61.0 57.0 57.0 66.0 66.0
      TOL °C -10 -10 -10 -10 -10 -10 -10 -10
      WTOL °C 55 55 55 55 55 55 55 55
    Tbiv (bivalent temperature) COPd   1.97 1.97 2.12 2.12 2.18 2.18 1.90 1.90
      Pdh kW 5.3 5.3 6.1 6.1 6.4 6.4 7.5 7.5
      PERd % 79.0 79.0 85.0 85.0 87.0 87.0 76.0 76.0
      Tbiv °C -7 -7 -6 -6 -6 -6 -8 -8
  Cold climate water outlet 55°C General Annual energy consumption kWh 4,468 4,468 5,300 5,300 7,066 7,066 6,886 6,886
      Ƞs (Seasonal space heating efficiency) % 107 107 109 109 109 109 112 112
      Prated at -22°C kW 5 5 6 6 8 8 8 8
  Warm climate water outlet 55°C General Annual energy consumption kWh 1,660 1,660 1,858 1,858 1,983 1,983 2,213 2,213
      Ƞs (Seasonal space heating efficiency) % 148 148 158 158 159 159 161 161
      Prated at 2°C kW 5 5 6 6 6 6 7 7
  Average climate water outlet 35°C General SCOP   4.48 4.48 4.47 4.47 4.56 4.56 4.56 4.56
      Annual energy consumption kWh 2,766 2,766 3,233 3,233 3,625 3,625 3,625 3,625
      Ƞs (Seasonal space heating efficiency) % 176 176 176 176 179 179 179 179
      Prated at -10°C kW 6.0 6.0 7.0 7.0 8 8 8.0 8.0
      Qhe Annual energy consumption (GCV) Gj 1 1 1 1 1 1 1 1
      Seasonal space heating eff. class   A++ A++ A++ A++ A++ A++ A++ A++
    A Condition (-7°CDB/-8°CWB) COPd   2.90 2.90 2.86 2.86 2.77 2.77 2.77 2.77
      Pdh kW 5.5 5.5 6.0 6.0 7.0 7.0 7.0 7.0
      PERd % 116.0 116.0 114.0 114.0 111.0 111.0 111.0 111.0
    B Condition (2°CDB/1°CWB) Cdh (Degradation heating)   1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
      COPd   4.33 4.33 4.25 4.25 4.35 4.35 4.35 4.35
      Pdh kW 3.3 3.3 3.9 3.9 4.2 4.2 4.2 4.2
      PERd % 173.0 173.0 170.0 170.0 174.0 174.0 174.0 174.0
    C Condition (7°CDB/6°CWB) Cdh (Degradation heating)   1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
      COPd   6.19 6.19 6.30 6.30 6.49 6.49 6.49 6.49
      Pdh kW 3.2 3.2 3.2 3.2 3.3 3.3 3.3 3.3
      PERd % 248.0 248.0 252.0 252.0 260.0 260.0 260.0 260.0
    D Condition (12°CDB/11°CWB) Cdh (Degradation heating)   1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
      COPd   7.78 7.78 7.78 7.78 8.52 8.52 8.52 8.52
      Pdh kW 3.3 3.3 3.3 3.3 3.9 3.9 3.9 3.9
      PERd % 311.0 311.0 311.0 311.0 341.0 341.0 341.0 341.0
    Tol (temperature operating limit) COPd   2.56 2.56 2.49 2.49 2.41 2.41 2.41 2.41
      Pdh kW 5.2 5.2 6.0 6.0 6.9 6.9 6.9 6.9
      PERd % 102.0 102.0 100.0 100.0 96.0 96.0 96.0 96.0
      TOL °C -10 -10 -10 -10 -10 -10 -10 -10
      WTOL °C 35 35 35 35 35 35 35 35
    Tbiv (bivalent temperature) COPd   2.90 2.90 2.49 2.49 2.66 2.66 2.66 2.66
      Pdh kW 5.5 5.5 6.0 6.0 7.5 7.5 7.5 7.5
      PERd % 116.0 116.0 100.0 100.0 106.0 106.0 106.0 106.0
      Tbiv °C -7 -7 -6 -6 -8 -8 -8 -8
    Rated heat output supplementary capacity Psup (at Tdesign -10°C) kW 0.8 0.8            
  Cold climate water outlet 35°C General Annual energy consumption kWh 3,230 3,230 3,749 3,749 5,052 5,052 5,034 5,034
      Ƞs (Seasonal space heating efficiency) % 150 150 155 155 153 153 154 154
      Prated at -22°C kW 5 5 6 6 8 8 8 8
  Warm climate water outlet 35°C General Annual energy consumption kWh 1,139 1,139 1,276 1,276 1,437 1,437 1,437 1,437
      Ƞs (Seasonal space heating efficiency) % 241 241 248 248 257 257 257 257
      Prated at 2°C kW 5 5 6 6 7 7 7 7
Notes Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )