EHVZ04S18CB3V |
EHVZ08S18CB3V |
EHVZ16S18CB3V |
Heater capacity |
Step 1 |
kW |
3 |
3 |
3 |
Power input |
Nom. |
kW |
0.14 |
0.14 |
0.20 |
Casing |
Colour |
|
White |
White |
White |
|
Material |
|
Precoated sheet metal |
Precoated sheet metal |
Precoated sheet metal |
Dimensions |
Unit |
Height |
mm |
1,732 |
1,732 |
1,732 |
|
|
Width |
mm |
600 |
600 |
600 |
|
|
Depth |
mm |
728 |
728 |
728 |
|
Packed unit |
Height |
mm |
1,922 |
1,922 |
1,922 |
|
|
Width |
mm |
690 |
690 |
690 |
|
|
Depth |
mm |
818 |
818 |
818 |
Weight |
Unit |
kg |
121 |
122 |
121 |
|
Packed unit |
kg |
138 |
139 |
138 |
Packing |
Material |
|
Wood, Carton, PE wrapping foil |
Wood, Carton, PE wrapping foil |
Wood, Carton, PE wrapping foil |
|
Weight |
kg |
17 |
17 |
17 |
PED |
Category |
|
Art3§3, See note 1 |
Category I, See note 1 |
Art3§3, See note 1 |
|
Most critical part |
Name |
|
Plate heat exchanger |
|
|
|
Ps*V |
Bar*l |
|
51 |
|
Pump Additional Zone |
Nr of speeds |
|
Inverter controlled |
Inverter controlled |
Inverter controlled |
|
Power input |
W |
46 |
46 |
70 |
|
Type |
|
DC motor |
DC motor |
DC motor |
Pump Main Zone |
Nr of speeds |
|
Inverter controlled |
Inverter controlled |
Inverter controlled |
|
Power input |
W |
46 |
46 |
70 |
|
Type |
|
DC motor |
DC motor |
DC motor |
Water side Heat exchanger |
Type |
|
Brazed plate |
Brazed plate |
Brazed plate |
|
Quantity |
|
1 |
1 |
1 |
|
Water volume |
l |
0.90 |
1.30 |
1.00 |
|
Water flow rate |
Min. |
l/min |
13.0 (2) |
13.0 (2) |
16.0 (2) |
|
|
Heating |
Nom. |
l/min |
13.0 |
21.5 |
46.0 |
|
Insulation material |
|
Elastomeric foam |
Elastomeric foam |
Elastomeric foam |
Expansion vessel |
Volume |
l |
10 |
10 |
10 |
|
Max. water pressure |
bar |
3 |
3 |
3 |
|
Pre pressure |
bar |
1 |
1 |
1 |
Water Filter Additional Zone |
Diameter perforations |
mm |
1.0 |
1.0 |
1.0 |
|
Material |
|
Copper - brass - stainless steel |
Copper - brass - stainless steel |
Copper - brass - stainless steel |
Water filter Main Zone |
Diameter perforations |
mm |
1.0 |
1.0 |
1.0 |
|
Material |
|
Copper - brass - stainless steel |
Copper - brass - stainless steel |
Copper - brass - stainless steel |
Tank |
Name |
|
Stainless steel domestic hot water tank 180 l |
Stainless steel domestic hot water tank 180 l |
Stainless steel domestic hot water tank 180 l |
|
Water volume |
l |
180 |
180 |
180 |
|
Material |
|
Stainless steel (EN 1.4521) |
Stainless steel (EN 1.4521) |
Stainless steel (EN 1.4521) |
|
Maximum water temperature |
°C |
65 (0.000) |
65 (0.000) |
65 (0.000) |
|
Maximum water pressure |
bar |
10 |
10 |
10 |
|
Insulation |
Material |
|
White polyester |
White polyester |
White polyester |
|
|
Heat loss |
kWh/24h |
1.4 (3) |
1.4 (3) |
1.4 (3) |
|
Corrosion protection |
|
Anode |
Anode |
Anode |
|
Energy efficiency class |
|
B |
B |
B |
|
Standing heat loss |
W |
58 |
58 |
58 |
|
Storage volume |
l |
166 |
166 |
166 |
|
Storage volume |
m³ |
0 |
0 |
0 |
Heat exchanger |
Domestic hot water |
Face area |
m² |
1.900 |
1.900 |
1.900 |
|
|
Internal coil volume |
l |
8.9 |
8.9 |
8.9 |
|
|
Quantity |
|
1 |
1 |
1 |
|
|
Tube material |
|
Stainless steel |
Stainless steel |
Stainless steel |
3-way valve |
Coefficient of flow (kV) |
Space heating |
m³/h |
13 |
13 |
13 |
|
|
Domestic hot water tank |
m³/h |
8 |
8 |
8 |
3-way valve mixing |
Coefficient of flow (kV) |
Bypass |
m³/h |
13 |
13 |
13 |
|
|
Main zone only |
m³/h |
8 |
8 |
8 |
Water circuit |
Total water volume |
l |
6.3 (5) |
6.7 (5) |
6.4 (5) |
Water circuit - space heating side (additional zone) |
Air purge valve |
|
Yes |
Yes |
Yes |
|
Drain valve / fill valve |
|
Yes, See note 4 |
Yes, See note 4 |
Yes, See note 4 |
|
Manometer |
|
Yes |
Yes |
Yes |
|
Piping connections diameter |
inch |
G 1-1/4 (FEMALE) |
G 1-1/4 (FEMALE) |
G 1-1/4 (FEMALE) |
|
Safety valve |
bar |
3 |
3 |
3 |
|
Shut off valve |
|
Yes |
Yes |
Yes |
Water circuit - space heating side (main zone) |
Air purge valve |
|
No |
No |
No |
|
Drain valve / fill valve |
|
Yes, See note 4 |
Yes, See note 4 |
Yes, See note 4 |
|
Manometer |
|
No |
No |
No |
|
Piping connections diameter |
inch |
G 1-1/4 (FEMALE) |
G 1-1/4 (FEMALE) |
G 1-1/4 (FEMALE) |
|
Safety valve |
bar |
Yes |
Yes |
Yes |
|
Shut off valve |
|
Yes |
Yes |
Yes |
Water circuit - Domestic hot water side |
Piping connections |
Cold water in / Hot water out |
inch |
G 3/4" FEMALE |
G 3/4" FEMALE |
G 3/4" FEMALE |
|
|
Recirculation connection |
inch |
G 1/2" FEMALE |
G 1/2" FEMALE |
G 1/2" FEMALE |
Refrigerant circuit |
Gas side diameter |
mm |
15.9 |
15.9 |
15.9 |
|
Liquid side diameter |
mm |
6.4 |
6.4 |
9.5 |
Sound power level |
Nom. |
dBA |
42 (6) |
42 (6) |
44 (6) |
Sound pressure level |
Nom. |
dBA |
28 (7) |
28 (7) |
30 (7) |
Operation range |
Heating |
Water side |
Min. |
°C |
15 (8) |
15 (8) |
15 (8) |
|
|
|
Max. |
°C |
55 |
55 |
55 (9) |
|
Indoor installation |
Ambient |
Min. |
°CDB |
5 |
5 |
5 |
|
|
|
Max. |
°CDB |
35 |
35 |
35 |
|
Domestic hot water |
Water side |
Min. |
°C |
25 |
25 |
25 |
|
|
|
Max. |
°C |
60 (10) |
60 (10) |
60 (10), 60 (11) |
Safety devices |
Item |
01 |
|
Thermal cut out |
Thermal cut out |
Thermal cut out |
Power supply |
Name |
|
See note 12 |
See note 12 |
See note 12 |
|
Voltage range |
Min. |
% |
-10 |
-10 |
-10 |
|
|
Max. |
% |
10 |
10 |
10 |
Class |
IP |
|
IP X0B |
IP X0B |
IP X0B |
Electric heater |
Power supply |
Name |
|
3V3 |
3V3 |
3V3 |
|
|
Phase |
|
1~ |
1~ |
1~ |
|
|
Frequency |
Hz |
50 |
50 |
50 |
|
|
Voltage |
V |
230 |
230 |
230 |
|
Current |
Running current |
A |
13.0 |
13.0 |
13.0 |
|
Voltage range |
Min. |
% |
-10 |
-10 |
-10 |
|
|
Max. |
% |
10 |
10 |
10 |
Wiring connections |
Communication cable |
Quantity |
|
3 |
3 |
3 |
|
|
Remark |
|
2.5 mm² |
2.5 mm² |
2.5 mm² |
|
Electric meter |
Quantity |
|
2 |
2 |
2 |
|
|
Remark |
|
Minimum 0.75 mm² (5VDC pulse detection) |
Minimum 0.75 mm² (5VDC pulse detection) |
Minimum 0.75 mm² (5VDC pulse detection) |
|
Preferential kWh rate power supply |
Quantity |
|
Power: 2 |
Power: 2 |
Power: 2 |
|
|
Remark |
|
Power 6.3A, See note 13 |
Power 6.3A, See note 13 |
Power 6.3A, See note 13 |
|
Domestic hot water pump |
Quantity |
|
2 |
2 |
2 |
|
|
Remark |
|
Minimum 0.75 mm² (2A inrush, 1A continuous) |
Minimum 0.75 mm² (2A inrush, 1A continuous) |
Minimum 0.75 mm² (2A inrush, 1A continuous) |
|
For power supply back-up heater |
Quantity |
|
3G |
3G |
3G |
|
|
Remark |
|
See note 13 |
See note 13 |
See note 13 |
|
For connection with R6T |
Quantity |
|
2 |
2 |
2 |
|
|
Remark |
|
Minimum 0.75 mm² |
Minimum 0.75 mm² |
Minimum 0.75 mm² |
|
For connection with A3P |
Quantity |
|
Depends on thermostat type, cf. installation manual |
Depends on thermostat type, cf. installation manual |
Depends on thermostat type, cf. installation manual |
|
|
Remark |
|
Voltage: 230V / Max. current: 100mA / Min. 0.75mm², See note 13 |
Voltage: 230V / Max. current: 100mA / Min. 0.75mm², See note 13 |
Voltage: 230V / Max. current: 100mA / Min. 0.75mm², See note 13 |
|
For connection with M2S |
Quantity |
|
2 |
2 |
2 |
|
|
Remark |
|
Voltage: 230V / Max. current: 100mA / Min. 0.75mm², See note 13 |
Voltage: 230V / Max. current: 100mA / Min. 0.75mm², See note 13 |
Voltage: 230V / Max. current: 100mA / Min. 0.75mm², See note 13 |
|
For connection with bottom plate heater |
Quantity |
|
2 |
2 |
2 |
|
|
Remark |
|
Voltage: 230V / Min. 0.75mm², See note 13 |
Voltage: 230V / Min. 0.75mm², See note 13 |
Voltage: 230V / Min. 0.75mm², See note 13 |
|
For connection with user interface |
Quantity |
|
2 |
2 |
2 |
|
|
Remark |
|
0.75 mm² till 1,25 mm² (max length 500m) |
0.75 mm² till 1,25 mm² (max length 500m) |
0.75 mm² till 1,25 mm² (max length 500m) |
|
For connection with optional FWXV* (demand input and output) |
Quantity |
|
4 |
4 |
4 |
|
|
Remark |
|
100 mA, minimum 0.75 mm² |
100 mA, minimum 0.75 mm² |
100 mA, minimum 0.75 mm² |
|
For connection with safety thermostat |
Quantity |
|
2 |
2 |
2 |
|
|
Remark |
|
Minimum 0.75 mm² |
Minimum 0.75 mm² |
Minimum 0.75 mm² |
Notes |
PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC |
PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC |
PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC |
|
Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). |
Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). |
Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). |
|
Heatloss according to EN12897 |
Heatloss according to EN12897 |
Heatloss according to EN12897 |
|
Drain/Fill valve only available on water inlet connection. |
Drain/Fill valve only available on water inlet connection. |
Drain/Fill valve only available on water inlet connection. |
|
Including piping + PHE + back-up heater; excluding expansion vessel |
Including piping + PHE + back-up heater; excluding expansion vessel |
Including piping + PHE + back-up heater; excluding expansion vessel |
|
DB/WB 7°C/6°C - LWC 35°C (DT=5°C) |
DB/WB 7°C/6°C - LWC 35°C (DT=5°C) |
DB/WB 7°C/6°C - LWC 35°C (DT=5°C) |
|
The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. |
The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. |
The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. |
|
15°C-25°C: BUH only, no heat pump operation = during commissioning |
15°C-25°C: BUH only, no heat pump operation = during commissioning |
15°C-25°C: BUH only, no heat pump operation = during commissioning |
|
Refer to operation range for detail for differences between *RHQ* and *RLQ* models |
Refer to operation range for detail for differences between *RHQ* and *RLQ* models |
Refer to operation range for detail for differences between *RHQ* and *RLQ* models |
|
For *RLQ* outdoor units >55°C BUH only, no heatpump operation |
For *RLQ* outdoor units >55°C BUH only, no heatpump operation |
For *RLQ* outdoor units >55°C BUH only, no heatpump operation |
|
For *RHQ* outdoor units >50°C BUH only, no heatpump operation |
For *RHQ* outdoor units >50°C BUH only, no heatpump operation |
For *RHQ* outdoor units >50°C BUH only, no heatpump operation |
|
Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the outdoor unit. |
Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the outdoor unit. |
Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the outdoor unit. |
|
Select diameter and type according to national and local regulations |
Select diameter and type according to national and local regulations |
Select diameter and type according to national and local regulations |