FBQ71C8VEB / RZQG71L9V1B FBQ100C8VEB / RZQG100L9V1B FBQ125C8VEB / RZQG125L9V1B
Poff (Off mode) W 0.0    
Cooling Psb (Standby mode cooling) W 7.0    
  Cooling-=-Cooling cdc degradation cooling 0.25    
Seasonal efficiency (according to EN14825) Cooling Pdesign kW 6.80    
    Annual energy consumption kWh 390    
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 5.61, 6.11    
    D Condition (20°C - 27/19) Pdc kW 4.06    
      power input kW 0.40    
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 10.18    
    C Condition (25°C - 27/19) power input kW 0.50    
      Pdc kW 3.92    
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 7.89    
    A Condition (35°C - 27/19) power input kW 1.95    
      Pdc kW 6.80    
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.50    
    B Condition (30°C - 27/19) Pdc kW 5.01    
      power input kW 1.05    
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 4.78    
  Heating (Average climate) Annual energy consumption kWh 2,095    
    Pdesign kW 6.00    
    Required back up heating cap at design conditions kW 0.28    
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scopnet a A+    
    TBivalent Pdh (declared heating cap) kW 5.31    
      Power input kW 1.89    
      Tbiv (bivalent temperature) °C -7    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.81    
    C Condition (7°C) Pdh (declared heating cap) kW 2.85    
      Power input kW 0.60    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 4.76    
    TOL Tol (temperature operating limit) °C -15    
      Pdh (declared heating cap) kW 6.38    
      Power input kW 3.23    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.98    
    A Condition (-7°C) Pdh (declared heating cap) kW 5.31    
      Power input kW 1.89    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.81    
    D Condition (12°C) Pdh (declared heating cap) kW 3.24    
      Power input kW 0.60    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 5.48    
    B Condition (2°C) Power input kW 0.76    
      Pdh (declared heating cap) kW 3.23    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.26    
Cooling capacity Nom. kW 6.8 9.5 12.0
Pck (Crankcase heater mode) W 0.0    
Nominal efficiency Annual energy consumption kWh 970 (0.000) 1,220 1,575
  Energy labeling Directive Heating A    
  Nominal efficiency-=-Cop 3.50    
Heating Psb (Standby mode heating) W 7.0    
  Heating-=-Heating cdh degradation heating 0.25    
Heating capacity Nom. kW 7.5 10.8 13.5
Pto (Thermostat off) W 7.0 9.0 9.0
Cold season included Yes    
Notes EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only
  Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
Nominal efficiency EER     3.89 3.81
  COP     4.21 3.83
  Energy labeling Directive Cooling     A A
    Heating     A A
Space cooling Energy efficiency class     A+ A+
  Capacity Pdesign kW   9.50 12.00
  SEER     5.80 5.81
  Annual energy consumption kWh/a   574 723
  A Condition (35°C - 27/19) Pdc kW   9.50 12.00
    EERd     3.89 3.81
    Power input kW   2.45 3.15
  B Condition (30°C - 27/19) Pdc kW   7.20 8.84
    EERd     4.17 4.59
    Power input kW   1.73 1.93
  C Condition (25°C - 27/19) Pdc kW   5.72 6.01
    EERd     7.52 6.92
    Power input kW   0.77 0.87
  D Condition (20°C - 27/19) Pdc kW   5.93 5.74
    EERd     9.77 8.66
    Power input kW   0.61 0.67
Space heating (Average climate) Energy efficiency class     A++ A+
  Capacity Pdesign kW   11.30 12.71
  SCOP/A     4.61 4.21
  SCOPnet/A     4.64 4.23
  Annual energy consumption kWh/a   3,432 4,227
  Required back up heating cap at design conditions kW   1.74 1.30
  TOL Tol (temperature operating limit) °C   -15 -15
    Pdh (declared heating cap) kW   8.82 11.67
    COPd (declared COP)     2.59 1.98
    Power input kW   3.41 5.90
  TBivalent Tbiv (bivalent temperature) °C   -7 -7
    Pdh (declared heating cap) kW   10.00 11.24
    COPd (declared COP)     3.48 2.72
    Power input kW   2.88 4.14
  A Condition (-7°C) Pdh (declared heating cap) kW   10.00 11.24
    COPd (declared COP)     3.48 2.72
    Power input kW   2.88 4.14
  B Condition (2°C) Pdh (declared heating cap) kW   6.12 7.18
    COPd (declared COP)     4.13 3.86
    Power input kW   1.49 1.87
  C Condition (7°C) Pdh (declared heating cap) kW   4.06 4.73
    COPd (declared COP)     6.48 6.26
    Power input kW   0.63 0.76
  D Condition (12°C) Pdh (declared heating cap) kW   4.65 5.39
    COPd (declared COP)     7.56 7.28
    Power input kW   0.62 0.75
Power consumption in other than active mode Standby mode Cooling PSB W   9.0 9.0
    Heating PSB W   9.0 9.0
  Crankcase heater mode PCK W   0.0 0.0
  Off mode POFF W   0.0 0.0
Cooling Cdc (Degradation cooling)     0.25 0.25
Heating Cdh (Degradation heating)     0.25 0.25
Cooling function included   Yes Yes
Heating function included   Yes Yes
Average climate included   Yes Yes
Cold season included   No No
Warm season included   No No
Ecolabel logo   No No