FBQ100D2VEB / RZQG71L9V1B FBQ140D2VEB / RZQG100L9V1B FBQ125D2VEB / RZQG125L9V1B FBQ140D2VEB / RZQG125L9V1B FBQ140D2VEB / RZQG140L9V1B
Indoor unit FBQ100D FBQ140D FBQ125D FBQ140D FBQ140D
Outdoor unit RZQG71L9V1 RZQG100L9V1 RZQG125L9V1 RZQG125L9V1 RZQG140L9V1
Cooling capacity Nom. kW     12.0 (2)   13.4 (2)
Heating capacity Nom. kW     13.50 (2)   15.50 (2)
Power input Cooling Nom. kW     3.63 (2)   4.00 (2)
  Heating Nom. kW     3.46 (2)   4.31 (2)
Nominal efficiency EER     3.31 (1)   3.35 (1)
  COP     3.90 (1)   3.60 (1)
  Annual energy consumption kWh     1,813 (0.000)    
  Energy labeling Directive Cooling     A    
    Heating     A    
Space cooling Energy efficiency class   A++ A+ A++ A++  
  Capacity Pdesign kW 6.80 9.50 12.00 12.00  
  SEER   6.16 5.87 6.11 6.11  
  Annual energy consumption kWh/a 386 566 687 687  
  A Condition (35°C - 27/19) Pdc kW 6.80 9.50 12.00 12.00  
    EERd   3.60 3.81 3.31 3.31  
    Power input kW 1.89 2.49 3.63 3.63  
  B Condition (30°C - 27/19) Pdc kW 5.01 7.00 8.84 8.84  
    EERd   5.42 4.39 5.09 5.09  
    Power input kW 0.92 1.59 1.74 1.74  
  C Condition (25°C - 27/19) Pdc kW 3.95 5.46 5.68 5.68  
    EERd   8.15 8.15 7.92 7.92  
    Power input kW 0.48 0.67 0.72 0.72  
  D Condition (20°C - 27/19) Pdc kW 4.08 5.80 5.61 5.61  
    EERd   10.19 10.50 9.87 9.87  
    Power input kW 0.40 0.55 0.57 0.57  
Space heating (Average climate) Energy efficiency class   A+ A++ A+ A+  
  Capacity Pdesign kW 6.00 11.30 12.70 12.70  
  SCOP/A   4.31 4.78 4.28 4.28  
  SCOPnet/A   4,347.00 4,846.00 4.32 4,321.00  
  Annual energy consumption kWh/a 1,949 3,310 4,154 4,154  
  Required back up heating cap at design conditions kW 1.09 3.19 3.05 3.05  
  TOL Tol (temperature operating limit) °C -15 -15 -15 -15  
    Pdh (declared heating cap) kW 4.24 4.97 6.58 6.58  
    COPd (declared COP)   2.05 2.69 2.01 2.01  
    Power input kW 2.07 1.85 3.27 3.27  
  TBivalent Tbiv (bivalent temperature) °C -7 -7 -7 -7  
    Pdh (declared heating cap) kW 5.31 10.00 11.23 11.23  
    COPd (declared COP)   3.02 3.55 2.72 2.72  
    Power input kW 1.76 2.82 4.13 4.13  
  A Condition (-7°C) Pdh (declared heating cap) kW 5.31 10.00 11.23 11.23  
    COPd (declared COP)   3.02 3.55 2.72 2.72  
    Power input kW 1.76 2.82 4.13 4.13  
  B Condition (2°C) Pdh (declared heating cap) kW 3.23 6.08 6.84 6.84  
    COPd (declared COP)   4.46 4.76 4.35 4.35  
    Power input kW 0.72 1.28 1.57 1.57  
  C Condition (7°C) Pdh (declared heating cap) kW 2.87 3.91 4.47 4.47  
    COPd (declared COP)   5.37 5.72 5.39 5.39  
    Power input kW 0.53 0.68 0.83 0.83  
  D Condition (12°C) Pdh (declared heating cap) kW 3.32 4.00 4.64 4.64  
    COPd (declared COP)   6.41 7.20 6.77 6.77  
    Power input kW 0.52 0.56 0.69 0.68  
Pto (Thermostat off) W 3.0 4.0 4.0 4.0  
Power consumption in other than active mode Standby mode Cooling PSB W 14.5 22.0   22.0  
  Crankcase heater mode PCK W 0.0 0.0   0.0  
  Off mode POFF W 14.5 22.0   22.0  
Cooling Cdc (Degradation cooling)   0.25 0.25 0.25 0.25  
Heating Cdh (Degradation heating)   0.25 0.25 0.25 0.25  
Cooling function included Yes Yes Yes Yes  
Heating function included Yes Yes Yes Yes  
Average climate included Yes Yes Yes Yes  
Cold season included No No No No  
Warm season included No No No No  
Ecolabel logo No No No No  
Power consumption in other than active mode Standby mode Cooling PSB W     22.0    
  Crankcase heater mode PCK W     0.0    
  Off mode POFF W     22.0    
Notes     EER/COP according to Eurovent 2012, for use outside EU only   EER/COP according to Eurovent 2012, for use outside EU only
      Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load   Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load