FTXM20N2V1B / RXM20M3V1B9 FTXM25N2V1B / RXM25M3V1B9 FTXM35N2V1B / RXM35M3V1B9
Indoor unit FTXM20N2V1B FTXM25N2V1B FTXM35N2V1B
Outdoor unit RXM20M3V1B9 RXM25M3V1B9 RXM35M3V1B9
Cooling capacity Min. kW 1.3 1.3 1.4
  Min. Btu/h 4,400 4,400 4,800
  Min. kcal/h 1,120 1,120 1,200
  Nom. kW 2.0 2.5 3.4
  Nom. Btu/h 6,800 8,500 11,600
  Nom. kcal/h 1,720 2,150 2,920
  Max. kW 2.6 3.2 4.0
  Max. Btu/h 8,900 11,000 13,600
  Max. kcal/h 2,240 2,750 3,440
Heating capacity Min. kW 1.30 1.30 1.40
  Min. Btu/h 4,400 4,400 4,800
  Min. kcal/h 1,120 1,120 1,200
  Nom. kW 2.50 2.80 4.00
  Nom. Btu/h 8,500 9,500 13,600
  Nom. kcal/h 2,150 2,400 3,440
  Max. kW 3.50 4.70 5.20
  Max. Btu/h 11,900 16,000 17,700
  Max. kcal/h 3,010 4,040 4,470
Power input Cooling Min. kW 0.27 0.27 0.31
    Nom. kW 0.44 0.56 0.80
    Max. kW 0.63 0.78 1.04
  Heating Min. kW 0.24 0.24 0.32
    Nom. kW 0.50 0.56 0.99
    Max. kW 0.91 1.22 1.67
Nominal efficiency EER   4.57 4.50 4.23
  COP   5.00 5.00 4.04
  Annual energy consumption kWh 220 280 400
  Energy labeling Directive Cooling   A A A
    Heating   A A A
Space cooling Capacity Pdesign kW 2.00 2.50 3.40
  Energy efficiency class   A+++ A+++ A+++
  SEER   8.53 8.52 8.51
  Annual energy consumption kWh/a 83 103 140
  A Condition (35°C - 27/19) Pdc kW 2.00 2.50 3.40
    EERd   4.57 4.50 4.23
    Power input kW 0.44 0.56 0.80
  B Condition (30°C - 27/19) Pdc kW 1.47 1.84 2.51
    EERd   6.85 6.42 6.08
    Power input kW 0.21 0.29 0.41
  C Condition (25°C - 27/19) Pdc kW 0.95 1.18 1.61
    EERd   10.73 10.70 10.28
    Power input kW 0.09 0.11 0.16
  D Condition (20°C - 27/19) Pdc kW 0.96 0.96 1.18
    EERd   14.56 14.68 16.50
    Power input kW 0.07 0.07 0.07
Space heating (Average climate) Capacity Pdesign kW 2.30 2.40 2.50
  Energy efficiency class   A+++ A+++ A+++
  SCOP/A   5.10 5.10 5.10
  SCOPnet/A   5.13 5.13 5.14
  Pdh Heating capacity at -10° kW 2.24 2.30 2.35
  Annual energy consumption kWh/a 632 659 686
  Required back up heating cap at design conditions kW 0.06 0.10 0.15
  TOL Tol (temperature operating limit) °C -15 -15 -15
    Pdh (declared heating cap) kW 2.59 2.59 2.59
    COPd (declared COP)   2.49 2.49 2.49
    Power input kW 1.04 1.04 1.04
  TBivalent Tbiv (bivalent temperature) °C -7 -7 -7
    Pdh (declared heating cap) kW 2.03 2.12 2.21
    COPd (declared COP)   3.57 3.51 3.50
    Power input kW 0.57 0.60 0.63
  A Condition (-7°C) Pdh (declared heating cap) kW 2.03 2.12 2.21
    COPd (declared COP)   3.57 3.51 3.50
    Power input kW 0.57 0.60 0.63
  B Condition (2°C) Pdh (declared heating cap) kW 1.24 1.29 1.34
    COPd (declared COP)   5.10 5.06 5.03
    Power input kW 0.24 0.25 0.27
  C Condition (7°C) Pdh (declared heating cap) kW 0.91 0.91 0.95
    COPd (declared COP)   6.33 6.32 6.43
    Power input kW 0.14 0.14 0.15
  D Condition (12°C) Pdh (declared heating cap) kW 1.09 1.09 1.09
    COPd (declared COP)   8.03 8.03 8.05
    Power input kW 0.14 0.14 0.14
Space heating (Warm climate) Capacity Pdesignh kW 1.24 1.29 1.34
  Energy efficiency class   A+++ A+++ A+++
  SCOP   6.12 6.21 6.28
  SCOPnet   6.32 6.41 6.48
  Annual energy consumption kWh/a 284 291 300
  Required back up heating cap at design conditions kW 0.00 0.00 0.00
  TOL Tol (temperature operating limit) °C -15 -15 -15
    Pdh (declared heating cap) kW 2.59 2.59 2.59
    COPd (declared COP)   2.49 2.49 2.49
    Power input kW 1.04 1.04 1.04
  TBivalent Tbiv (bivalent temperature) °C 2 2 2
    Pdh (declared heating cap) kW 1.24 1.29 1.34
    COPd (declared COP)   5.10 5.06 5.03
    Power input kW 0.24 0.25 0.27
  B Condition (2°C) Pdh (declared heating cap) kW 1.24 1.29 1.34
    COPd (declared COP)   5.10 5.06 5.03
    Power input kW 0.24 0.25 0.27
  C Condition (7°C) Pdh (declared heating cap) kW 0.91 0.91 0.95
    COPd (declared COP)   6.33 6.32 6.43
    Power input kW 0.14 0.14 0.15
  D Condition (12°C) Pdh (declared heating cap) kW 1.1 1.1 1.1
    COPd (declared COP)   8.03 8.03 8.05
    Power input kW 0.14 0.14 0.14
Power consumption in other than active mode Off mode POFF W 1.0 1.0 1.0
  Standby mode Cooling PSB W 1.0 1.0 1.0
Cooling Cdc (Degradation cooling)   0.25 0.25 0.25
Heating Cdh (Degradation heating)   0.25 0.25 0.25
Cooling function included Yes Yes Yes
Heating function included Yes Yes Yes
Average climate included Yes Yes Yes
Cold season included No No No
Warm season included Yes Yes Yes
Ecolabel logo No No No
Eurovent Sound power level outdoor Cooling Nom. dBA 59 59 61
  Sound power level indoor Cooling Nom. dBA 57 57 58
  Piping length Cooling Measuring condition m 5.0 5.0 5.0
Power factor Nominal Cooling % 91.10 (0.000) 93.90 (0.000) 79.90 (0.000)
    Heating % 97.60 (0.000) 98.20 (0.000) 90.00 (0.000)
Current Nominal running current (RLA) - 50Hz Cooling A 2.1 2.6 4.4
    Heating A 2.2 2.5 4.8
Notes (1) - See separate drawing for electrical data (1) - See separate drawing for electrical data (1) - See separate drawing for electrical data
  (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.