FVXM50FV1B / RXM50N2V1B
Indoor unit FVXM50FV1B
Outdoor unit RXM50N2V1B
Cooling capacity Min. kW 1.40
  Min. Btu/h 4,776
  Min. kcal/h 1,203
  Nom. kW 5.00
  Nom. Btu/h 17,061
  Nom. kcal/h 4,299
  Max. kW 5.60
  Max. Btu/h 19,107
  Max. kcal/h 4,815
Heating capacity Min. kW 1.40
  Min. Btu/h 4,766
  Min. kcal/h 1,203
  Nom. kW 5.80
  Nom. Btu/h 19,790
  Nom. kcal/h 4,987
Power input Cooling Nom. kW 1.55
  Heating Nom. kW 1.60
Nominal efficiency EER   3.23
  COP   3.63
  Annual energy consumption kWh 773 (0.000)
  Energy labeling Directive Cooling   A
    Heating   A
Space cooling Energy efficiency class   A++
  Capacity Pdesign kW 5.00
  SEER   6.80
  Annual energy consumption kWh/a 257
  A Condition (35°C - 27/19) Pdc kW 5.00
    EERd   3.23
    Power input kW 1.55
  B Condition (30°C - 27/19) Pdc kW 3.68
    EERd   5.50
    Power input kW 0.67
  C Condition (25°C - 27/19) Pdc kW 2.38
    EERd   8.92
    Power input kW 0.27
  D Condition (20°C - 27/19) Pdc kW 2.29
    EERd   12.49
    Power input kW 0.18
Space heating (Average climate) Energy efficiency class   A+
  Capacity Pdesign kW 4.20
  SCOP/A   4.00
  SCOPnet/A   4.01
  Pdh Heating capacity at -10° kW 3.81
  Annual energy consumption kWh/a 1,471
  Required back up heating cap at design conditions kW 0.39
  TOL Tol (temperature operating limit) °C -15
    Pdh (declared heating cap) kW 3.96
    COPd (declared COP)   1.82
    Power input kW 2.18
  TBivalent Tbiv (bivalent temperature) °C -7
    Pdh (declared heating cap) kW 3.72
    COPd (declared COP)   2.20
    Power input kW 1.69
  A Condition (-7°C) Pdh (declared heating cap) kW 3.72
    COPd (declared COP)   2.20
    Power input kW 1.69
  B Condition (2°C) Pdh (declared heating cap) kW 2.27
    COPd (declared COP)   4.32
    Power input kW 0.53
  C Condition (7°C) Pdh (declared heating cap) kW 1.80
    COPd (declared COP)   5.13
    Power input kW 0.35
  D Condition (12°C) Pdh (declared heating cap) kW 1.91
    COPd (declared COP)   6.25
    Power input kW 0.31
Space heating (Warm climate) Energy efficiency class   A++
  Capacity Pdesignh kW 2.27
  SCOP   4.91
  SCOPnet   5.01
  Annual energy consumption kWh/a 647
  Required back up heating cap at design conditions kW 0.00
  TOL Tol (temperature operating limit) °C -15
    Pdh (declared heating cap) kW 3.96
    COPd (declared COP)   1.82
    Power input kW 2.18
  TBivalent Tbiv (bivalent temperature) °C 2
    Pdh (declared heating cap) kW 2.27
    COPd (declared COP)   4.32
    Power input kW 0.53
  B Condition (2°C) Pdh (declared heating cap) kW 2.27
    COPd (declared COP)   4.32
    Power input kW 0.53
  C Condition (7°C) Pdh (declared heating cap) kW 1.80
    COPd (declared COP)   5.13
    Power input kW 0.35
  D Condition (12°C) Pdh (declared heating cap) kW 1.91
    COPd (declared COP)   6.25
    Power input kW 0.31
Power consumption in other than active mode Standby mode Cooling PSB kW 8.0
    Heating PSB kW 8.0
  Thermostat-off mode Cooling PTO kW 9.9
    Heating PTO kW 16.0
Cooling Cdc (Degradation cooling)   0.25
Heating Cdh (Degradation heating)   0.25
Cooling function included Yes
Heating function included Yes
Average climate included Yes
Cold season included No
Warm season included Yes
Ecolabel logo No
Eurovent Sound power level outdoor Cooling Nom. dBA 62.0
  Sound power level indoor Cooling Nom. dBA 57.0
  Piping length Cooling Measuring condition m 5.0
Notes See separate drawing for operation range
  See separate drawing for electrical data
  Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.