FVXM25FV1B9 / RXTP25N2V1B9 FVXM35FV1B9 / RXTP35N2V1B9
Cooling capacity Min. kW 1.00 1.10
  Min. Btu/h 3,400 3,800
  Min. kcal/h 860 946
  Nom. kW 2.50 3.50
  Nom. Btu/h 8,500 11,900
  Nom. kcal/h 2,150 3,009
  Max. kW 4.20 4.30
  Max. Btu/h 14,300 14,700
  Max. kcal/h 3,611 3,697
Heating capacity Min. kW 1.00 1.10
  Min. Btu/h 3,400 3,800
  Min. kcal/h 900 900
  Nom. kW 3.20 4.00
  Nom. Btu/h 10,900 13,600
  Nom. kcal/h 2,752 3,439
  Max. kW 5.60 6.00
  Max. Btu/h 19,100 20,500
  Max. kcal/h 4,815 5,159
Power input Cooling Nom. kW 0.69 1.06
  Heating Nom. kW 0.83 1.13
Nominal efficiency EER   3.61 3.31
  COP   3.86 3.54
  Annual energy consumption kWh 346 529
  Energy labeling Directive Cooling   A A
    Heating   A B
Space cooling Capacity Pdesign kW 2.50 3.50
  Energy efficiency class   A+ A+
  SEER   5.61 5.66
  Annual energy consumption kWh/a 156 216
  A Condition (35°C - 27/19) Pdc kW 2.50 3.50
    EERd   3.61 3.31
    Power input kW 0.69 1.06
  B Condition (30°C - 27/19) Pdc kW 1.85 2.58
    EERd   5.01 4.97
    Power input kW 0.37 0.52
  C Condition (25°C - 27/19) Pdc kW 1.19 1.66
    EERd   7.48 7.45
    Power input kW 0.16 0.22
  D Condition (20°C - 27/19) Pdc kW 0.79 0.84
    EERd   5.96 5.89
    Power input kW 0.13 0.14
Space heating (Average climate) Capacity Pdesign kW 2.50 3.00
  Energy efficiency class   A+ A+
  SCOP/A   4.05 4.01
  SCOPnet/A   4.05 4.02
  Pdh Heating capacity at -10° kW 2.50 3.00
  Annual energy consumption kWh/a 865 1,046
  Required back up heating cap at design conditions kW 0.00 0.00
  TOL Tol (temperature operating limit) °C -25 -25
    Pdh (declared heating cap) kW 2.91 3.02
    COPd (declared COP)   1.42 1.41
    Power input kW 2.05 2.14
  TBivalent Tbiv (bivalent temperature) °C -10 -10
    Pdh (declared heating cap) kW 2.50 3.00
    COPd (declared COP)   2.28 2.12
    Power input kW 1.10 1.42
  A Condition (-7°C) Pdh (declared heating cap) kW 2.22 2.66
    COPd (declared COP)   2.84 2.52
    Power input kW 0.78 1.06
  B Condition (2°C) Pdh (declared heating cap) kW 1.35 1.62
    COPd (declared COP)   3.95 3.99
    Power input kW 0.34 0.41
  C Condition (7°C) Pdh (declared heating cap) kW 0.87 1.21
    COPd (declared COP)   5.04 5.35
    Power input kW 0.17 0.23
  D Condition (12°C) Pdh (declared heating cap) kW 1.04 1.05
    COPd (declared COP)   6.41 6.58
    Power input kW 0.16 0.16
Space heating (Cold climate) Capacity Pdesignh kW 3.65 4.38
  Energy efficiency class   B B
  SCOP/C   3.31 3.20
  SCOPnet/C   3.34 3.24
  Annual energy consumption kWh/a 2,315 2,877
  Required back up heating cap at design conditions kW 0.72 1.19
  TOL Tol (temperature operating limit) °C -25 -25
    Pdh (declared heating cap) kW 2.91 3.02
    COPd (declared COP)   1.42 1.41
    Power input kW 2.05 2.14
  TBivalent Tbiv (bivalent temperature) °C -15 -15
    Pdh (declared heating cap) kW 2.98 3.58
    COPd (declared COP)   1.90 1.87
    Power input kW 1.57 1.91
  A Condition (-15°C) Pdh (declared heating cap) kW 2.98 3.58
    COPd (declared COP)   1.90 1.87
    Power input kW 1.57 1.91
  A Condition (-7°C) Pdh (declared heating cap) kW 2.22 2.66
    COPd (declared COP)   2.84 2.52
    Power input kW 0.78 1.06
  B Condition (2°C) Pdh (declared heating cap) kW 1.35 1.62
    COPd (declared COP)   3.95 3.99
    Power input kW 0.34 0.41
  C Condition (7°C) Pdh (declared heating cap) kW 0.87 1.21
    COPd (declared COP)   5.04 5.35
    Power input kW 0.17 0.23
  D Condition (12°C) Pdh (declared heating cap) kW 1.04 1.05
    COPd (declared COP)   6.41 6.58
    Power input kW 0.16 0.16
Power consumption in other than active mode Crankcase heater mode PCK W 0 0
  Off mode POFF W 2 2
  Standby mode Cooling PSB W 2 2
    Heating PSB W 2 2
  Thermostat-off mode PTO Cooling W 8 8
      Heating W 10 10
Cooling Cdc (Degradation cooling)   0.25 0.25
Heating Cdh (Degradation heating)   0.25 0.25
Cooling function included Yes Yes
Heating function included Yes Yes
Average climate included Yes Yes
Cold season included Yes Yes
Warm season included No No
Eurovent Sound power level outdoor Cooling Nom. dBA 61 61
  Sound power level indoor Cooling Nom. dBA 52 52
  Piping length Cooling Measuring condition m 5.00 5.00
Power factor Nominal Cooling % 95.00 (0.000) 98.91 (0.000)
    Heating % 98.80 (0.000) 99.18 (0.000)
Current Nominal running current (RLA) - 50Hz Cooling A 2.77 4.11
    Heating A 3.73 4.69
Current - 50Hz Maximum fuse amps (MFA) A 16.00 16.00
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for operation range (3) - See separate drawing for operation range
  (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data