Specifications Table for HYC 3XX

HYC 343/19/0-DB HYC 343/0/0-DB HYC 343/19/0-P
Mounting Floor Floor Floor
Casing Colour   Traffic white (RAL9016) / Dark grey (RAL7011) Traffic white (RAL9016) / Dark grey (RAL7011) Traffic white (RAL9016) / Dark grey (RAL7011)
  Material   Impact resistant polypropylene Impact resistant polypropylene Impact resistant polypropylene
Dimensions Unit Height Tank mm 1,650 1,650 1,650
    Width mm 595 595 595
    Depth mm 615 615 615
Weight Unit Empty kg 58 54 58
    Full kg 358 354 358
Tank Water volume l 294 294 294
  Material   Polypropylen Polypropylen Polypropylen
  Maximum water temperature °C 85 (0.000) 85 (0.000) 85 (0.000)
  Energy efficiency class   B B B
  Standing heat loss W 64 64 64
Heat exchanger Domestic hot water Quantity   1 1 1
    Tube material   Stainless steel (DIN 1.4404) Stainless steel (DIN 1.4404) Stainless steel (DIN 1.4404)
    Face area 5.600 5.600 5.600
    Internal coil volume l 27.1 27.1 27.1
    Operating pressure bar 6 6 6
    Average specifc thermal output W/K 2,790 2,790 2,790
  Charging Quantity   1   1
    Tube material   Stainless steel (DIN 1.4404)   Stainless steel (DIN 1.4404)
    Face area 3   3
    Internal coil volume l 13   13
    Operating pressure bar 3   3
    Average specifc thermal output W/K 1,300   1,300
Notes Indoor temperature : 29°CDB, 19°CWB; outdoor temperature : 46°CDB, 24°CWB Indoor temperature : 29°CDB, 19°CWB; outdoor temperature : 46°CDB, 24°CWB Indoor temperature : 29°CDB, 19°CWB; outdoor temperature : 46°CDB, 24°CWB
  Indoor temperature : 27°CDB, 19°CWB; outdoor temperature : 35°CDB, 24°CWB Indoor temperature : 27°CDB, 19°CWB; outdoor temperature : 35°CDB, 24°CWB Indoor temperature : 27°CDB, 19°CWB; outdoor temperature : 35°CDB, 24°CWB
  Indoor temperature : 21°CDB, 15°CWB; outdoor temperature : 7°CDB, 6°CWB Indoor temperature : 21°CDB, 15°CWB; outdoor temperature : 7°CDB, 6°CWB Indoor temperature : 21°CDB, 15°CWB; outdoor temperature : 7°CDB, 6°CWB
  Indoor temperature : 20°CDB, 15°CWB; outdoor temperature : 7°CDB, 6°CWB. Indoor temperature : 20°CDB, 15°CWB; outdoor temperature : 7°CDB, 6°CWB. Indoor temperature : 20°CDB, 15°CWB; outdoor temperature : 7°CDB, 6°CWB.
  Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m
  Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  12/day 12/day 12/day