MALTA145_EU_403758 MALTA145_UK_403782 MALTA185_EU_403759 MALTA185_UK_403783
Classification acc. EN 23953-2 L1 L1 L1 L1
Climate class acc. EN 23953-2 3 3 3 3
Energy efficiency index EEI-=-% % 52.9 52.9 46.7 46.7
Use Display & Sale Display & Sale Display & Sale Display & Sale
Dimensions Dimensions-=-Gross content-=-l l 603 (0.000) 603 (0.000) 795 (0.000) 795 (0.000)
  Dimensions-=-Net content-=-l l 425 (2.000) 425 (2.000) 571 (2.000) 571 (2.000)
  Dimensions-=-Total display area (TDA)-=-m² 0.73 (2) 0.73 (2) 0.99 (2) 0.99 (2)
  Dimensions-=-Length Dimensions-=-Length-=-Outside-=-mm mm 1,456 1,456 1,851 1,851
    Dimensions-=-Length-=-Inside-=-mm mm 1,328 1,328 1,723 1,723
  Dimensions-=-Depth Dimensions-=-Depth-=-Outside-=-mm mm 855 855 855 855
    Dimensions-=-Depth-=-Inside-=-mm mm 723 723 723 723
  Dimensions-=-Height Dimensions-=-Height-=-Outside - front-=-mm mm 770 770 770 770
    Dimensions-=-Height-=-Outside - rear-=-mm mm 833 833 833 833
    Dimensions-=-Height-=-Inside - front-=-mm mm 655 655 655 655
    Dimensions-=-Height-=-Inside - rear-=-mm mm 655 655 655 655
  Dimensions-=-Stacking height Dimensions-=-Stacking height-=-Front-=-mm mm 550 (2.000) 550 (2.000) 550 (2.000) 550 (2.000)
    Dimensions-=-Stacking height-=-Rear-=-mm mm 550 (2.000) 550 (2.000) 550 (2.000) 550 (2.000)
Net weight-=-kg kg 103 (2.000) 103 (2.000) 122 (2.000) 122 (2.000)
Gross weight-=-kg kg 110 (2.000) 110 (2.000) 132 (2.000) 132 (2.000)
Operation range Ambient temperature Min. °C 16 16 16 16
    Max. °C 25 25 25 25
  Relative humidity % 60 or less 60 or less 60 or less 60 or less
  Operation range-=-Product temperature Operation range-=-Product temperature-=-Min.-=-°C °C -23 -23 -23 -23
    Operation range-=-Product temperature-=-Max.-=-°C °C -18 -18 -18 -18
  Operation range-=-Sound pressure in 1m distance-=-dB(A) dB(A) 43.6 43.6 43.6 43.6
  Operation range-=-Blowing agent   R-601 (HC) GWP 5 R-601 (HC) GWP 5 R-601 (HC) GWP 5 R-601 (HC) GWP 5
Daily energy consumption Daily energy consumption-=-Edaily-=-kWh/day kWh/day 6.70 (1) 6.70 (1) 7.30 (1) 7.30 (1)
Annual energy consumption Annual energy consumption-=-AE-=-kWh/a kWh/a 2,445.50 2,445.50 2,664.50 2,664.50
HVAC-=-Rejected heat capacity W 279 279 304 304
HVAC-=-Dehumidification Liter/day 0 0 0 0
Refrigerant Type   R-290 R-290 R-290 R-290
  GWP   3 3 3 3
  Refrigerant-=-Charge-=-g g 80 80 90 90
  Refrigerant-=-Max. allowable operating pressure-=-bar bar 30 30 30 30
Power supply Voltage V 220-240 220-240 220-240 220-240
  Frequency Hz 50 50 50 50
  Power supply-=-Nominal power acc. EN 60335-2-89-=-W W 460 460 460 460
  Power supply-=-Nominal power during defrost-=-W W 900 900 900 900
  Power supply-=-Nominal current during defrost-=-A A 3.9 3.9 3.9 3.9
  Power supply-=-Nominal power LED-=-W W 20 20 25 25
  Power supply-=-Fuse protection   RCBO, 30mA, C16 RCBO, 30mA, C16 RCBO, 30mA, C16 RCBO, 30mA, C16
  Power supply-=-Defrost heater power-=-W W 0 0 0 0
  Power supply-=-Cord length-=-mm mm 2,400 2,400 2,400 2,400
Notes (1) - Energy test results are declared for climate class 3, test procedure according to EN 23953-2 (initial door openings, 12h LED switched on with door openings, one defrost per day) (1) - Energy test results are declared for climate class 3, test procedure according to EN 23953-2 (initial door openings, 12h LED switched on with door openings, one defrost per day) (1) - Energy test results are declared for climate class 3, test procedure according to EN 23953-2 (initial door openings, 12h LED switched on with door openings, one defrost per day) (1) - Energy test results are declared for climate class 3, test procedure according to EN 23953-2 (initial door openings, 12h LED switched on with door openings, one defrost per day)
  (2) - With process-related interior fitting (2) - With process-related interior fitting (2) - With process-related interior fitting (2) - With process-related interior fitting