VAPLE1750AAW1 VAPLE3000AAW1 VAPLE4000AAW1 VAPLE7000AAW1 VAPLE9000AAW1
Panels Inner skin material Foam Foam Foam Foam Foam
Return filter Air velocity m/s 1.86 2.12 2.02 2.66 2.28
  Clean differential pressure Pa 42 55 50 85 62
  Primary filter Thickness mm 47 47 47 47 47
    Filter 1 Height mm 508 610 305 305 610
      Width mm 508 610 610 610 305
    Type Panel filter Panel filter Panel filter Panel filter Panel filter
  Mean differential pressure Pa 96 102 100 117 106
  Air flow rate m³/s 0.48 0.79 1.13 1.98 2.54
  Dirty differential pressure Pa 150 150 150 150 150
  Quantity Fibre glass Fibre glass Fibre glass Fibre glass Fibre glass
Supply filter Primary filter Filter 1 Width mm 508 610 610 610 305
      Height mm 508 610 305 305 610
    Mean differential pressure Pa 96 102 100 117 106
    Air velocity m/s 1.86 2.12 2.02 2.66 2.28
    Thickness mm 47 47 47 47 47
    Air flow rate m³/s 0.48 0.79 1.13 1.98 2.54
    Clean differential pressure Pa 42 55 50 85 62
    Dirty differential pressure Pa 150 150 150 150 150
    Quantity Fibre glass Fibre glass Fibre glass Fibre glass Fibre glass
Heating coil Air side Temperature off °CDB 20.00 20.00 20.00 20.00 20.00
    Pressure drop Pa 31 31 31 31 28
    Air flow m³/s 0.48 0.79 1.13 1.98 2.54
    Temperature on °CDB -5.00 -5.00 -5.00 -5.00 -5.00
  Tube diameter inch 5/8"  5/8"  5/8"  5/8"  5/8" 
  Rows Quantity 2 2 2 2 2
  Coils Quantity 1 1 1 1 1
  Fluid side Max pressure drop kPa 15 15 15 15 15
    Temperature on °C 82.00 82.00 82.00 82.00 82.00
    Fluid flow kg/s 0.31 0.51 0.74 1.30 1.66
    Temperature off °C 71.00 71.00 71.00 71.00 71.00
    Fluid velocity m/s 0.84 1.38 0.99 0.99 1.27
    Pressure drop kPa 3 11 4 5 9
  Fin space mm 3.00 2.5 2.5 2.50 2.5
  Total capacity kW 14.54 23.94 34.24 60.00 76.97
  Water connections Al Al Al Al Al
Supply fan Total pressure Pa 661 677 639 721 693
  Motor Quantity EFF1 EFF1 EFF1 EFF1 EFF1
  External static pressure Pa 250 250 250 250 250
  Total static pressure Pa 583 590 568 633 601
  Air flow m³/s 0.48 0.79 1.13 1.98 2.54
  Sound power (LWS) dB 79 (5), 78 (6), 77 (7), 73 (8), 73 (9), 78 (10), 74 (11), 70 (12) 80 (5), 80 (6), 78 (7), 76 (8), 80 (9), 79 (10), 77 (11), 73 (12) 80 (5), 79 (6), 78 (7), 75 (8), 80 (9), 77 (10), 76 (11), 72 (12) 83 (5), 79 (6), 78 (7), 76 (8), 79 (9), 75 (10), 74 (11), 71 (12) 83 (5), 81 (6), 79 (7), 79 (8), 83 (9), 80 (10), 79 (11), 73 (12)
  Rotation speed rpm 2,593 2,029 1,561 1,294 1,119
  Component static pressure Pa 333 340 318 383 351
  Dynamic pressure Pa 78 87 71 88 92
  Efficiency % 48.32 58.85 61.18 65.03 65.85
  Model Door without porthole, Drive screen Door without porthole, Drive screen Door without porthole, Drive screen Door without porthole, Drive screen Door without porthole, Drive screen
  Absence power kW 0.66 0.91 1.18 2.20 2.67
  Motor Frequency Hz 50 50 50 50 50
    Voltage V 400 400 400 400 400
    Power kW 1.10 1.50 1.50 3.00 4.00
    Poles Quantity 2 4 4 4 4
Dimensions Unit base Height (1) mm 100 100 100 100 100
    Height (2) mm 100 100 100 100 100
  Return Overall width mm 654 754 1,054 1,054 1,354
    Net overall height mm 690 790 790 1,090 1,090
  Unit Length without damper mm 2,450 2,650 2,500 3,150 2,850
    Length with damper mm 2,580 2,780 2,630 3,280 2,980
  Supply Overall width mm 654 754 1,054 1,054 1,354
    Net overall height mm 690 790 790 1,090 1,090
Nominal air flow Supply air flow m³/s 0.48 0.79 1.13 1.98 2.54
  Return air flow m³/s 0.48 0.79 1.13 1.98 2.54
Heat cube with bypass Edge mm 501 701 601 801 801
  Warm air summer Temperature off °CDB 27.30 27.30 27.60 27.70 27.50
    Flow rate m³/s 0.48 0.79 1.13 1.98 2.54
    Temperature on °CDB 32.00 32.00 32.00 32.00 32.00
    Pressure drop Pa 220 221 200 241 231
  Warm air winter Temperature on °CDB -5.00 -5.00 -5.00 -5.00 -5.00
    Pressure drop Pa 210 210 190 230 220
    Flow rate m³/s 0.48 0.79 1.13 1.98 2.54
    Temperature off °CDB 8.10 8.10 7.40 7.10 7.80
  Cold air winter Flow rate m³/s 0.48 0.79 1.13 1.98 2.54
    Temperature on °CDB 22.00 22.00 22.00 22.00 22.00
    Temperature off °CDB 9.70 9.80 10.50 10.70 10.10
    Pressure drop Pa 200 200 181 219 209
  Length mm 550 650 950 950 1,250
  Cold air summer Temperature off °CDB 26.70 26.70 26.40 26.30 26.50
    Temperature on °CDB 22.00 22.00 22.00 22.00 22.00
    Pressure drop Pa 217 217 196 237 227
    Flow rate m³/s 0.48 0.79 1.13 1.98 2.54
  Options Drain standard sloping - Polypropylene, Extend actuator rod (for external linkage) Drain standard sloping - Polypropylene, Extend actuator rod (for external linkage) Drain standard sloping - Polypropylene, Extend actuator rod (for external linkage) Drain standard sloping - Polypropylene, Extend actuator rod (for external linkage) Drain standard sloping - Polypropylene, Extend actuator rod (for external linkage)
Return fan Sound power (LWS) dB 66 (5), 70 (6), 73 (7), 71 (8), 73 (9), 78 (10), 74 (11), 70 (12) 68 (5), 73 (6), 75 (7), 75 (8), 80 (9), 79 (10), 77 (11), 73 (12) 68 (5), 71 (6), 74 (7), 74 (8), 79 (9), 76 (10), 75 (11), 71 (12) 73 (5), 73 (6), 76 (7), 76 (8), 79 (9), 75 (10), 74 (11), 71 (12) 73 (5), 76 (6), 77 (7), 79 (8), 83 (9), 80 (10), 79 (11), 73 (12)
  Component static pressure Pa 306 312 291 346 326
  Motor Quantity EFF1 EFF1 EFF1 EFF1 EFF1
  Total pressure Pa 634 650 612 685 668
  Dynamic pressure Pa 78 87 71 88 92
  External static pressure Pa 250 250 250 250 250
  Efficiency % 48.01 57.20 59.43 62.90 63.42
  Air flow m³/s 0.48 0.79 1.13 1.98 2.54
  Rotation speed rpm 2,542 2,013 1,548 1,280 1,119
  Total static pressure Pa 556 562 541 596 576
  Options Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal
  Motor Voltage V 400 400 400 400 400
    Power kW 1.10 1.10 1.50 3.00 4.00
    Frequency Hz 50 50 50 50 50
    Poles Quantity 2 4 4 4 4
  Absence power kW 0.63 0.90 1.16 2.16 2.67
Damper Height mm 590 690 690 990 990
  Pressure drop Pa 5.00 5.00 5.00 5.24 5.06
  Torque Nm 15.00 15.00 15.00 15.00 15.00
  Width mm 554 654 954 954 1,254
  Options Middle Middle Middle Middle Middle
Supply fan Poles Quantity 2 4 4 4 4
  Motor Frequency Hz 50 50 50 50 50
    Voltage V 400 400 400 400 400
    Power kW 1.10 1.50 1.50 3.00 4.00
    Poles Quantity 2 4 4 4 4
  Power kW 1.10 1.50 1.50 3.00 4.00
  Frequency Hz 50 50 50 50 50
  Voltage V 400 400 400 400 400
Return fan Motor Voltage V 400 400 400 400 400
    Power kW 1.10 1.10 1.50 3.00 4.00
    Frequency Hz 50 50 50 50 50
    Poles Quantity 2 4 4 4 4
  Poles Quantity 2 4 4 4 4
  Frequency Hz 50 50 50 50 50
  Power kW 1.10 1.10 1.50 3.00 4.00
  Voltage 400 400 400 400 400
Notes All information in this report should be considered as indicative and can be subject to variations All information in this report should be considered as indicative and can be subject to variations All information in this report should be considered as indicative and can be subject to variations All information in this report should be considered as indicative and can be subject to variations All information in this report should be considered as indicative and can be subject to variations
  To be finalised in our general arrangement drawing. To be finalised in our general arrangement drawing. To be finalised in our general arrangement drawing. To be finalised in our general arrangement drawing. To be finalised in our general arrangement drawing.
  Individual sections are supplied for site assembly by others and support legs (if applicable) are supplied loose for site fitting by others Individual sections are supplied for site assembly by others and support legs (if applicable) are supplied loose for site fitting by others Individual sections are supplied for site assembly by others and support legs (if applicable) are supplied loose for site fitting by others Individual sections are supplied for site assembly by others and support legs (if applicable) are supplied loose for site fitting by others Individual sections are supplied for site assembly by others and support legs (if applicable) are supplied loose for site fitting by others
  All quoted fan volumes and noise levels are provided with the relevant fan manufacturers standard and are subject to industry accepted tolerances. All quoted fan volumes and noise levels are provided with the relevant fan manufacturers standard and are subject to industry accepted tolerances. All quoted fan volumes and noise levels are provided with the relevant fan manufacturers standard and are subject to industry accepted tolerances. All quoted fan volumes and noise levels are provided with the relevant fan manufacturers standard and are subject to industry accepted tolerances. All quoted fan volumes and noise levels are provided with the relevant fan manufacturers standard and are subject to industry accepted tolerances.
  63Hz 63Hz 63Hz 63Hz 63Hz
  125Hz 125Hz 125Hz 125Hz 125Hz
  250Hz 250Hz 250Hz 250Hz 250Hz
  500Hz 500Hz 500Hz 500Hz 500Hz
  1kHz 1kHz 1kHz 1kHz 1kHz
  2kHz 2kHz 2kHz 2kHz 2kHz
  4kHz 4kHz 4kHz 4kHz 4kHz
  8kHz 8kHz 8kHz 8kHz 8kHz
Return filter Primary filter Filter 2 Width mm     610 305 305
      Height mm     610 610 610
Supply filter Primary filter Filter 2 Height mm     610 610 610
      Width mm     610 305 305
Return filter Primary filter Filter 3 Height mm       610 610
      Width mm       610 610
Supply filter Primary filter Filter 3 Height mm       610 610
      Width mm       610 610
Return filter Primary filter Filter 4 Height mm         610
      Width mm         610
Supply filter Primary filter Filter 4 Height mm         610
      Width mm         610