Specifications Table for ARXS-L

ARXS50L2V1B ARXS60L2V1B ARXS71L2V1B ARXS25L2V1B (Archived) ARXS35L2V1B (Archived)
Dimensions Unit Height Mm 735     550 550
    Width Mm 825     765 765
    Depth Mm 300     285 285
Weight Unit kg 47     34 34
Compressor Type   Hermetically sealed swing compressor     Hermetically sealed swing compressor Hermetically sealed swing compressor
Fan Air flow rate Cooling Super low cfm 1,727     1,063 1,063
    Heating Super low cfm 1,522     904 904
Fan motor Speed Cooling Super low rpm 670     780 780
    Heating Super low rpm 670     740 740
Sound pressure level Cooling High dBA 48     46 48
  Heating High dBA 48     47 48
Refrigerant Type   R-410A     R-410A R-410A
  Charge kg 1.7     1.0 1.2
  Charge TCO2Eq 3.5     2.1 2.5
  GWP   2,087.5     2,087.5 2,087.5
Piping connections Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m)     0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m)
  Level difference IU - OU Max. m 20     15 15
Standard Accessories Drain plug 1 1 1 1 1
  Installation manual 1 1 1 1 1
  Refrigerant charge label   1 1 1  
  Multilingual fluorinated greenhouse gases labels   1 1 1  
Power supply Phase   1~     1~ 1~
  Frequency Hz 50     50 50
  Voltage V 220-240     220-240 220-240
Notes (1) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected.     (1) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected. (1) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected.
  (2) - 220V     (2) - 220V (2) - 220V
  (3) - 230V     (3) - 230V (3) - 230V
  (4) - 240V     (4) - 240V (4) - 240V
  (5) - Contains fluorinated greenhouse gases     (5) - Contains fluorinated greenhouse gases (5) - Contains fluorinated greenhouse gases