CYQL100DK125CSN |
CYQL100DK125CBN |
CYQL150DK200CSN |
CYQL150DK200CBN |
CYQL200DK250CSN |
CYQL250DK250CSN |
CYQL200DK250CBN |
CYQL250DK250CBN |
Power input |
Fan only |
Nom. |
kW |
0.75 |
0.75 |
1.13 |
1.13 |
1.50 |
1.88 |
1.50 |
1.88 |
|
Heating |
Nom. |
kW |
0.75 |
0.75 |
1.13 |
1.13 |
1.50 |
1.88 |
1.50 |
1.88 |
Door width |
Max. |
m |
1.0 |
1.0 |
1.5 |
1.5 |
2.0 |
2.5 |
2.0 |
2.5 |
Door height |
Max. |
m |
3.0 (2), 2.75 (3), 2.5 (4) |
3.0 (2), 2.75 (3), 2.5 (4) |
3.0 (2), 2.75 (3), 2.5 (4) |
3.0 (2), 2.75 (3), 2.5 (4) |
3.0 (2), 2.75 (3), 2.5 (4) |
3.0 (2), 2.75 (3), 2.5 (4) |
3.0 (2), 2.75 (3), 2.5 (4) |
3.0 (2), 2.75 (3), 2.5 (4) |
Dimensions |
Unit |
Height |
Mm |
370 |
370 |
370 |
370 |
370 |
370 |
370 |
370 |
|
|
Width |
Mm |
1,000 |
1,000 |
1,500 |
1,500 |
2,000 |
2,500 |
2,000 |
2,500 |
|
|
Depth |
Mm |
1,105 |
1,105 |
1,105 |
1,105 |
1,105 |
1,105 |
1,105 |
1,105 |
Weight |
Unit |
kg |
81 |
81 |
118 |
118 |
151 |
190 |
151 |
190 |
Casing |
Colour |
|
RAL9006 |
RAL9016 |
RAL9006 |
RAL9016 |
RAL9006 |
RAL9006 |
RAL9016 |
RAL9016 |
|
Material |
|
Electro-galvanised sheet steel |
Electro-galvanised sheet steel |
Electro-galvanised sheet steel |
Electro-galvanised sheet steel |
Electro-galvanised sheet steel |
Electro-galvanised sheet steel |
Electro-galvanised sheet steel |
Electro-galvanised sheet steel |
Required ceiling void >-=-mm |
Mm |
520 |
520 |
520 |
520 |
520 |
520 |
520 |
520 |
Refrigerant |
Type |
|
R-410A |
R-410A |
R-410A |
R-410A |
R-410A |
R-410A |
R-410A |
R-410A |
|
GWP |
|
2,087.5 |
2,087.5 |
2,087.5 |
2,087.5 |
2,087.5 |
2,087.5 |
2,087.5 |
2,087.5 |
Piping connections |
Liquid |
OD |
Mm |
9.52 |
9.52 |
9.52 |
9.52 |
9.52 |
9.52 |
9.52 |
9.52 |
|
Gas |
OD |
Mm |
16.0 |
16.0 |
19.0 |
19.0 |
22.0 |
22.0 |
22.0 |
22.0 |
Power supply |
Frequency |
Hz |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
|
Voltage |
V |
230 |
230 |
230 |
230 |
230 |
230 |
230 |
230 |
Notes |
(1) - Installation level B: standard setting, refer to the databook of installation manual for more information (only one installation level available) |
(1) - Installation level B: standard setting, refer to the databook of installation manual for more information (only one installation level available) |
(1) - Installation level B: standard setting, refer to the databook of installation manual for more information (only one installation level available) |
(1) - Installation level B: standard setting, refer to the databook of installation manual for more information (only one installation level available) |
(1) - Installation level B: standard setting, refer to the databook of installation manual for more information (only one installation level available) |
(1) - Installation level B: standard setting, refer to the databook of installation manual for more information (only one installation level available) |
(1) - Installation level B: standard setting, refer to the databook of installation manual for more information (only one installation level available) |
(1) - Installation level B: standard setting, refer to the databook of installation manual for more information (only one installation level available) |
|
(2) - Favorable conditions: covered shopping mall or revolving door entrance |
(2) - Favorable conditions: covered shopping mall or revolving door entrance |
(2) - Favorable conditions: covered shopping mall or revolving door entrance |
(2) - Favorable conditions: covered shopping mall or revolving door entrance |
(2) - Favorable conditions: covered shopping mall or revolving door entrance |
(2) - Favorable conditions: covered shopping mall or revolving door entrance |
(2) - Favorable conditions: covered shopping mall or revolving door entrance |
(2) - Favorable conditions: covered shopping mall or revolving door entrance |
|
(3) - Normal conditions: little direct wind, no opposite open doors, building with ground floor only |
(3) - Normal conditions: little direct wind, no opposite open doors, building with ground floor only |
(3) - Normal conditions: little direct wind, no opposite open doors, building with ground floor only |
(3) - Normal conditions: little direct wind, no opposite open doors, building with ground floor only |
(3) - Normal conditions: little direct wind, no opposite open doors, building with ground floor only |
(3) - Normal conditions: little direct wind, no opposite open doors, building with ground floor only |
(3) - Normal conditions: little direct wind, no opposite open doors, building with ground floor only |
(3) - Normal conditions: little direct wind, no opposite open doors, building with ground floor only |
|
(4) - Unfavorable conditions: location at a corner or square, multiple floors and/or open stairway |
(4) - Unfavorable conditions: location at a corner or square, multiple floors and/or open stairway |
(4) - Unfavorable conditions: location at a corner or square, multiple floors and/or open stairway |
(4) - Unfavorable conditions: location at a corner or square, multiple floors and/or open stairway |
(4) - Unfavorable conditions: location at a corner or square, multiple floors and/or open stairway |
(4) - Unfavorable conditions: location at a corner or square, multiple floors and/or open stairway |
(4) - Unfavorable conditions: location at a corner or square, multiple floors and/or open stairway |
(4) - Unfavorable conditions: location at a corner or square, multiple floors and/or open stairway |
|
(5) - Sound pressure level (at 3m) |
(5) - Sound pressure level (at 3m) |
(5) - Sound pressure level (at 3m) |
(5) - Sound pressure level (at 3m) |
(5) - Sound pressure level (at 3m) |
(5) - Sound pressure level (at 3m) |
(5) - Sound pressure level (at 3m) |
(5) - Sound pressure level (at 3m) |
|
(6) - Pipe work and electrical connections are on top of the unit |
(6) - Pipe work and electrical connections are on top of the unit |
(6) - Pipe work and electrical connections are on top of the unit |
(6) - Pipe work and electrical connections are on top of the unit |
(6) - Pipe work and electrical connections are on top of the unit |
(6) - Pipe work and electrical connections are on top of the unit |
(6) - Pipe work and electrical connections are on top of the unit |
(6) - Pipe work and electrical connections are on top of the unit |
|
(7) - Contains fluorinated greenhouse gases |
(7) - Contains fluorinated greenhouse gases |
(7) - Contains fluorinated greenhouse gases |
(7) - Contains fluorinated greenhouse gases |
(7) - Contains fluorinated greenhouse gases |
(7) - Contains fluorinated greenhouse gases |
(7) - Contains fluorinated greenhouse gases |
(7) - Contains fluorinated greenhouse gases |