Specifications Table for EBHQ-BBV3

EBHQ006BBV3 EBHQ008BBV3
Heating capacity Nom. kW 6.00 (2), 5.58 (4) 8.85 (2), 8.15 (4)
Cooling capacity Nom. kW 7.00 (1), 5.12 (3) 8.37 (1), 6.08 (3)
Power input Cooling Nom. kW 2.20 (1), 2.16 (3) 2.97 (1), 2.75 (3)
  Heating Nom. kW 1.41 (2), 1.79 (4) 2.21 (2), 2.72 (4)
COP 4.26 (2), 3.11 (4) 4.00 (2), 3.00 (4)
EER 3.18 (1), 2.37 (3) 2.82 (1), 2.21 (3)
Dimensions Unit Height Mm 805 805
    Width Mm 1,190 1,190
    Depth Mm 360 360
Weight Unit kg 95 95
  Operation weight kg 99 99
Sound power level Heating Nom. dBA 61 62
  Cooling Nom. dBA 63 63
Sound pressure level Heating Nom. dBA 48 (6) 49 (6)
  Cooling Nom. dBA 48 (6) 50 (6)
Refrigerant Type   R-410A R-410A
  GWP   2,087.5 2,087.5
  Charge kg 1.7 1.7
  Charge TCO2Eq 3.5 3.5
Compressor component Main power supply Name   V3 V3
    Phase   1~ 1~
    Frequency Hz 50 50
    Voltage V 230 230
Notes (1) - Tamb 35°C - LWE 18°C (DT=5°C) (1) - Tamb 35°C - LWE 18°C (DT=5°C)
  (2) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) (2) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
  (3) - Tamb 35°C - LWE 7°C (DT=5°C) (3) - Tamb 35°C - LWE 7°C (DT=5°C)
  (4) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) (4) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)
  (5) - Pump power input is included in heating and cooling power input (5) - Pump power input is included in heating and cooling power input
  (6) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. (6) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information.
  (7) - 15°C-25°C: BUH only, no heat pump operation = during commissioning (7) - 15°C-25°C: BUH only, no heat pump operation = during commissioning
  (8) - Including piping + PHE; excluding expansion vessel (8) - Including piping + PHE; excluding expansion vessel
  (9) - Excluding water volume in the unit. In most applications this minimum water volume will have a satisfying result. In critical processes or in rooms with a high heat load though, extra water volume might be required. Refer to operation range for more info. (9) - Excluding water volume in the unit. In most applications this minimum water volume will have a satisfying result. In critical processes or in rooms with a high heat load though, extra water volume might be required. Refer to operation range for more info.
  (10) - The 3-way valve should be mounted as close as possible to the outdoor unit (10) - The 3-way valve should be mounted as close as possible to the outdoor unit
  (11) - Power supply compressor compartment is for compressor, fan, pump and controller (11) - Power supply compressor compartment is for compressor, fan, pump and controller
  (12) - Minimum Ssc value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase (12) - Minimum Ssc value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase
  (13) - In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax (13) - In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax
  (14) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A (14) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A
  (15) - Wiring connections: cf. connection diagram for full wiring overview; Select diameter and type according to local regulations; For more details on voltage range and current cf. EBHQ installation manual (15) - Wiring connections: cf. connection diagram for full wiring overview; Select diameter and type according to local regulations; For more details on voltage range and current cf. EBHQ installation manual
  (16) - See separate drawing for operation range (16) - See separate drawing for operation range
  (17) - Contains fluorinated greenhouse gases (17) - Contains fluorinated greenhouse gases
  (17) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (17) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC