Specifications Table for 2MXM-A

2MXM50A2V1B
Dimensions Unit Height mm 552
    Width mm 852
    Depth mm 350
Weight Unit kg 41
Compressor Type   Hermetically sealed swing compressor
Operation range Cooling Ambient Min. °CDB -10
      Max. °CDB 46
Sound pressure level Cooling Nom. dBA 48
  Heating Nom. dBA 50
Refrigerant Type   R-32
  Charge kg 1.15
  Charge tCO2Eq 0.78
  GWP   675
Piping connections Piping length OU - IU Max. m 20 (1)
  Additional refrigerant charge kg/m 0.02 (for piping length exceeding 20m)
  Level difference IU - OU Max. m 15
    IU - IU Max. m 7.5
  Total piping length System Actual m 30
Standard Accessories Installation manual 1
  Drain plug 1
  Reducer assembly 1
  Screw bag 1
Energy Efficiency Range A+++ ~ D
Power supply Phase   1~
  Frequency Hz 50
  Voltage V 220-240
Notes (1) - For one room
  (2) - For combination with CVXM-A, FVXM-A - maximum piping length is 30m.
  (3) - See separate drawing for operation range
  (4) - See separate drawing for electrical data
  (5) - Contains fluorinated greenhouse gases