Specifications Table for 3MXM-N7

3MXM40N2V1B7 3MXM52N2V1B7 3MXM68N2V1B7
Fan Air flow rate Cooling Super low m³/min     24.1
    Heating Super low m³/min     24.1
      Super low cfm     851
    Heating Super low cfm     851
Dimensions Unit Height mm 734 734 734
    Width mm 974 974 958
    Depth mm 401 401 340
Weight Unit kg 57 57 62
Fan motor Speed Cooling Super low rpm 420 420
    Heating Super low rpm 420 420
Compressor Type   Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor
Operation range Cooling Ambient Min. °CDB -10 -10 -10
      Max. °CDB 46 46 46
  Heating Ambient Min. °CWB     -15
      Max. °CWB     24
Sound pressure level Cooling Nom. dBA 46 46 48
  Heating Nom. dBA 47 47 48
Refrigerant Type   R-32 R-32 R-32
  Charge kg 1.8 1.8 2
  Charge tCO2Eq 1.22 1.22
  GWP   675 675 675
Piping connections Piping length OU - IU Max. m 25 25 (1) 25
  Additional refrigerant charge kg/m 0.02 (for piping length exceeding 30m) 0.02 (for piping length exceeding 30m) 0.02 (for piping length exceeding 30m)
  Level difference IU - OU Max. m 15.0 15.0 15
    IU - IU Max. m 7.5 7.5 7.5
  Total piping length System Actual m 50 50 (2) 50
Standard Accessories Installation manual 1 1 1
  Drain cap 3 3 3
  Drain plug 1 1 1
  Reducer assembly 1 1 1
  Screw bag 1 1 1
Power supply Phase   1~ 1~ 1~
  Frequency Hz 50 50 50
  Voltage V 220-240 220-240 220-440
Notes (1) - For one room (1) - For one room
  (2) - For combination with CVXM-A, FVXM-A - maximum piping length is 30m. (2) - For combination with CVXM-A, FVXM-A - maximum piping length is 30m.
Energy Efficiency Range     A+++ ~ D