| ATXF20F5V1B / ARXF20J5V1B | ATXF25F5V1B / ARXF25J5V1B | ATXF35F5V1B / ARXF35J5V1B | ATXF42F5V1B / ARXF42J5V1B | ||||
|---|---|---|---|---|---|---|---|
| Outdoor unit | ARXF20J5V1B | ARXF25J5V1B | ARXF35J5V1B | ARXF42J5V1B | |||
| Cooling capacity | Min. | kW | 1.3 | 1.3 | 1.3 | 1.4 | |
| Nom. | kW | 2.00 | 2.50 | 3.30 | 4.20 | ||
| Max. | kW | 2.4 | 2.8 | 3.8 | 4.3 | ||
| Heating capacity | Min. | kW | 1.30 | 1.30 | 1.30 | 1.40 | |
| Nom. | kW | 2.40 | 2.80 | 3.50 | 4.60 | ||
| Max. | kW | 3.30 | 3.70 | 4.40 | 5.00 | ||
| Nominal efficiency | EER | 3.33 | 3.24 | 3.27 | 3.27 | ||
| COP | 3.75 | 3.73 | 3.72 | 3.71 | |||
| Annual energy consumption | kWh | 109 | 137 | 191 | 228 | ||
| Energy labeling Directive | Cooling | A | A | A | A | ||
| Heating | A | A | A | A | |||
| Space cooling | Energy efficiency class | A++ | A++ | A++ | A++ | ||
| Capacity | Pdesign | kW | 2.00 | 2.50 | 3.50 | 4.20 | |
| SEER | 6.55 | 6.70 | 6.67 | 6.70 | |||
| Annual energy consumption | kWh/a | 107 | 131 | 184 | 219 | ||
| Space heating (Average climate) | Energy efficiency class | A+ | A+ | A+ | A+ | ||
| Capacity | Pdesign | kW | 2.20 | 2.40 | 2.60 | 3.30 | |
| SCOP/A | 4.16 | 4.20 | 4.20 | 4.25 | |||
| Pdh Heating capacity at -10° | kW | 1.86 | 1.97 | 2.21 | 2.61 | ||
| Annual energy consumption | kWh/a | 740 | 799 | 866 | 1087 | ||
| Energy Efficiency Range | A+++ ~ D | A+++ ~ D | A+++ ~ D | A+++ ~ D | |||
| Notes | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified | |||
| (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series | ||||
| (3) - See separate drawing for electrical data | (3) - See separate drawing for electrical data | (3) - See separate drawing for electrical data | (3) - See separate drawing for electrical data | ||||