Specifications Table for CHVX-A

CHVX07S18AJ4V CHVX07S18AJ9W CHVX07S23AJ4V CHVX07S23AJ9W
Casing Colour   White + Black White + Black White + Black White + Black
  Material   Precoated sheet metal Precoated sheet metal Precoated sheet metal Precoated sheet metal
Dimensions Unit Height mm 1655 1655 1855 1855
    Width mm 597 597 597 597
    Depth mm 634 634 634 634
Weight Unit kg 113 113 121 121
PED Category   See note 1 See note 1 See note 1 See note 1
Sound power level Nom. dBA 44.0 (5) 44.0 (5) 44.0 (5) 44.0 (5)
Sound pressure level Nom. dBA 30.0 (5) 30.0 (5) 30.0 (5) 30.0 (5)
Operation range Heating Water side Min. °C 18 (6) 18 (6) 18 (6) 18 (6)
      Max. °C 55 (6) 55 (6) 55 (6) 55 (6)
  Cooling Ambient Min. °CDB 10 (6) 10 (6) 10 (6) 10 (6)
    Water side Min. °C 18 (6) 18 (6) 18 (6) 18 (6)
      Max. °C 22 (6) 22 (6) 22 (6) 22 (6)
Power supply Name   See note 7 See note 7 See note 7 See note 7
Electric heater Power supply Name   4V 9W 4V 9W
    Phase   1~ / 3~ 3~ 1~ / 3~ 3~
    Frequency Hz 50 50 50 50
    Voltage V 230/400 400 230/400 400
  Recommended fuses A 0.000 (8) 0.000 (8) 0.000 (8) 0.000 (8)
Notes (1) - Assembly ≤ category I: excluded from 2014/68/EU due to article 1, 2f (1) - Assembly ≤ category I: excluded from 2014/68/EU due to article 1, 2f (1) - Assembly ≤ category I: excluded from 2014/68/EU due to article 1, 2f (1) - Assembly ≤ category I: excluded from 2014/68/EU due to article 1, 2f
  (2) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). (2) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). (2) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). (2) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation).
  (3) - Based on dT of 45 K (3) - Based on dT of 45 K (3) - Based on dT of 45 K (3) - Based on dT of 45 K
  (4) - Including piping + PHE + back-up heater; excluding expansion vessel (4) - Including piping + PHE + back-up heater; excluding expansion vessel (4) - Including piping + PHE + back-up heater; excluding expansion vessel (4) - Including piping + PHE + back-up heater; excluding expansion vessel
  (5) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. (5) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. (5) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. (5) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°.
  (6) - For more details, see operation range drawing (6) - For more details, see operation range drawing (6) - For more details, see operation range drawing (6) - For more details, see operation range drawing
  (7) - Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the outdoor unit. The optional domestic hot water tank has a separate power supply. (7) - Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the outdoor unit. The optional domestic hot water tank has a separate power supply. (7) - Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the outdoor unit. The optional domestic hot water tank has a separate power supply. (7) - Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the outdoor unit. The optional domestic hot water tank has a separate power supply.
  (8) - Refer to wiring diagram and installation manual for correct recommended fuse depending on power supply and grid connection (8) - Refer to wiring diagram and installation manual for correct recommended fuse depending on power supply and grid connection (8) - Refer to wiring diagram and installation manual for correct recommended fuse depending on power supply and grid connection (8) - Refer to wiring diagram and installation manual for correct recommended fuse depending on power supply and grid connection