Specifications Table for EHBX-CB

EHBX04CB3V EHBX08CB3V EHBX08CB9W EHBX11CB3V EHBX11CB9W EHBX16CB3V EHBX16CB9W
Casing Colour   White White White White White White White
  Material   Precoated sheet metal Precoated sheet metal Precoated sheet metal Precoated sheet metal Precoated sheet metal Precoated sheet metal Precoated sheet metal
Dimensions Unit Height mm 890 890 890 890 890 890 890
    Width mm 480 480 480 480 480 480 480
    Depth mm 344 344 344 344 344 344 344
Weight Unit kg 42.0 44.0 45.0 43.0 45.0 44.0 46.0
PED Category   Art3§3, See note 1 Category I, See note 1 Category I, See note 1 Art3§3, See note 1 Art3§3, See note 1 Art3§3, See note 1 Art3§3, See note 1
Sound power level Nom. dBA 40.0 40.0 40.0 41.0 (4) 41.0 (4) 44.0 (4) 44.0 (4)
Sound pressure level Nom. dBA 26.0 26.0 26.0 27.0 (5) 27.0 (5) 30.0 (5) 30.0 (5)
Operation range Heating Water side Min. °C 15 15 15 15 (6) 15 (6) 15 (6) 15 (6)
      Max. °C 55.0 55.0 55.0 55.0 (8) 55.0 (8) 55.0 (8) 55.0 (8)
  Cooling Water side Min. °C 5.00 5.00 5.00 5.00 (9) 5.00 (9) 5.00 (9) 5.00 (9)
      Max. °C 22.0 22.0 22.0 22.0 22.0 22.0 22.0
Power supply Name   See note 11 See note 11 See note 11 See note 11 See note 11 See note 11 See note 11
Electric heater Power supply Name   3V3 3V3 9W 3V3 9W 3V3 9W
    Phase   1~ 1~ Refer to installation manual or drawing 4D093592 1~ Refer to installation manual or drawing 4D093592 1~ Refer to installation manual or drawing 4D093592
    Frequency Hz 50 50 50 50 50 50 50
    Voltage V 230 230   230   230
Wiring connections For connection with user interface Quantity   2 2 2 2 2 2 2
    Remark   0.75 mm² till 1.25 mm² (max length 500m) 0.75 mm² till 1.25 mm² (max length 500m) 0.75 mm² till 1.25 mm² (max length 500m) 0.75 mm² till 1.25 mm² (max length 500m) 0.75 mm² till 1.25 mm² (max length 500m) 0.75 mm² till 1.25 mm² (max length 500m) 0.75 mm² till 1.25 mm² (max length 500m)
Notes (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation).
  (2) - Including piping + PHE + back-up heater; excluding expansion vessel (2) - Including piping + PHE + back-up heater; excluding expansion vessel (2) - Including piping + PHE + back-up heater; excluding expansion vessel (2) - Including piping + PHE + back-up heater; excluding expansion vessel (2) - Including piping + PHE + back-up heater; excluding expansion vessel (2) - Including piping + PHE + back-up heater; excluding expansion vessel (2) - Including piping + PHE + back-up heater; excluding expansion vessel
  (3) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) (3) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) (3) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) (3) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) (3) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) (3) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) (3) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
  (4) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.The sound pressure level mentioned is maximum possible value inside operation range of unit. (4) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.The sound pressure level mentioned is maximum possible value inside operation range of unit. (4) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.The sound pressure level mentioned is maximum possible value inside operation range of unit. (4) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.The sound pressure level mentioned is maximum possible value inside operation range of unit. (4) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.The sound pressure level mentioned is maximum possible value inside operation range of unit. (4) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.The sound pressure level mentioned is maximum possible value inside operation range of unit. (4) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.The sound pressure level mentioned is maximum possible value inside operation range of unit.
  (5) - 15°C-25°C: BUH only no heat pump operation = during commissioning (5) - 15°C-25°C: BUH only no heat pump operation = during commissioning (5) - 15°C-25°C: BUH only no heat pump operation = during commissioning (5) - 15°C-25°C: BUH only no heat pump operation = during commissioning (5) - 15°C-25°C: BUH only no heat pump operation = during commissioning (5) - 15°C-25°C: BUH only no heat pump operation = during commissioning (5) - 15°C-25°C: BUH only no heat pump operation = during commissioning
  (6) - If condensation is expected, the installation of a EKHBDP* drain pan kit must be considered. (6) - If condensation is expected, the installation of a EKHBDP* drain pan kit must be considered. (6) - If condensation is expected, the installation of a EKHBDP* drain pan kit must be considered. (6) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models (6) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models (6) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models (6) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models
  (7) - > 50°C BSH only, no heatpump (7) - > 50°C BSH only, no heatpump (7) - > 50°C BSH only, no heatpump (7) - If condensation is expected, the installation of a EKHBDP* drain pan kit must be considered. (7) - If condensation is expected, the installation of a EKHBDP* drain pan kit must be considered. (7) - If condensation is expected, the installation of a EKHBDP* drain pan kit must be considered. (7) - If condensation is expected, the installation of a EKHBDP* drain pan kit must be considered.
        (8) - > 50°C BSH only, no heatpump (8) - > 50°C BSH only, no heatpump (8) - > 50°C BSH only, no heatpump (8) - > 50°C BSH only, no heatpump