| EWYQ009ACV3 | EWYQ010ACV3 | EWYQ011ACV3 | |||||
|---|---|---|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 12.2 (1), 8.60 (2) | 13.6 (1), 9.60 (2) | 11.1 (2), 15.7 (1) | ||
| Capacity control | Method | Inverter controlled | Inverter controlled | Inverter controlled | |||
| Power input | Cooling | Nom. | kW | 2.83 (2), 2.85 (1) | 3.28 (2), 3.41 (1) | 3.90 (2), 4.13 (1) | |
| EER | 3.05 (2), 4.27 (1) | 2.93 (2), 4.00 (1) | 2.85 (2), 3.79 (1) | ||||
| Dimensions | Unit | Depth | mm | 382 | 382 | 382 | |
| Height | mm | 1,435 | 1,435 | 1,435 | |||
| Width | mm | 1,420 | 1,420 | 1,420 | |||
| Weight | Unit | kg | 180 | 180 | 180 | ||
| Casing | Colour | Ivory white | Ivory white | Ivory white | |||
| Material | Painted galvanized steel plate | Painted galvanized steel plate | Painted galvanized steel plate | ||||
| Air heat exchanger | Type | Hi-XSS (8) | Hi-XSS (8) | Hi-XSS (8) | |||
| Fan | Quantity | 2 | 2 | 2 | |||
| Type | Propeller fan | Propeller fan | Propeller fan | ||||
| Fan motor | Drive | Direct drive | Direct drive | Direct drive | |||
| Compressor | Quantity | 1 | 1 | 1 | |||
| Type | Hermetically sealed scroll compressor | Hermetically sealed scroll compressor | Hermetically sealed scroll compressor | ||||
| Starting method | Inverter driven | Inverter driven | Inverter driven | ||||
| Operation range | Air side | Cooling | Min. | °CDB | 10 | 10 | 10 |
| Max. | °CDB | 46 | 46 | 46 | |||
| Water side | Evaporator | Min. | °CDB | 5 | 5 | 5 | |
| Max. | °CDB | 20 | 20 | 20 | |||
| Sound power level | Cooling | Nom. | dBA | 64.0 (3) | 64.0 (3) | 64.0 (3) | |
| Sound pressure level | Cooling | Nom. | dBA | 50 (3) | 50 (3) | 50 (3) | |
| Refrigerant | Type | R-410A | R-410A | R-410A | |||
| GWP | 2,087.5 | 2,087.5 | 2,087.5 | ||||
| Circuits | Quantity | 1 | 1 | 1 | |||
| Power supply | Phase | 1~ | 1~ | 1~ | |||
| Frequency | Hz | 50 | 50 | 50 | |||
| Voltage | V | 230 | 230 | 230 | |||
| Voltage range | Min. | % | -10 | -10 | -10 | ||
| Max. | % | 10 | 10 | 10 | |||
| Notes | (1) - Underfloor program: cooling Ta 35°C - LWE 18°C (Dt: 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (Dt: 5°C) | (1) - Underfloor program: cooling Ta 35°C - LWE 18°C (Dt: 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (Dt: 5°C) | (1) - Underfloor program: cooling Ta 35°C - LWE 18°C (Dt: 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (Dt: 5°C) | ||||
| (2) - Fan coil program: cooling Ta 35°C - LWE 7°C ( Dt: 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( Dt: 5°C ) | (2) - Fan coil program: cooling Ta 35°C - LWE 7°C ( Dt: 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( Dt: 5°C ) | (2) - Fan coil program: cooling Ta 35°C - LWE 7°C ( Dt: 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( Dt: 5°C ) | |||||
| (3) - Condition: Ta 35°C - LWE 7°C ( DT = 5°C) | (3) - Condition: Ta 35°C - LWE 7°C ( DT = 5°C) | (3) - Condition: Ta 35°C - LWE 7°C ( DT = 5°C) | |||||
| (4) - Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | (4) - Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | (4) - Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | |||||
| (5) - Including piping + PHE; excluding expansion vessel | (5) - Including piping + PHE; excluding expansion vessel | (5) - Including piping + PHE; excluding expansion vessel | |||||
| (6) - Excluding water volume in the unit. In most applications this minimum water volume will have a satisfying result. In critical processes or in rooms with a high heat load though, extra water volume might be required. Refer to operation range for more info. | (6) - Excluding water volume in the unit. In most applications this minimum water volume will have a satisfying result. In critical processes or in rooms with a high heat load though, extra water volume might be required. Refer to operation range for more info. | (6) - Excluding water volume in the unit. In most applications this minimum water volume will have a satisfying result. In critical processes or in rooms with a high heat load though, extra water volume might be required. Refer to operation range for more info. | |||||
| (7) - Contains fluorinated greenhouse gases | (7) - Contains fluorinated greenhouse gases | (7) - Contains fluorinated greenhouse gases | |||||