| FDXM25F3V1B9 / FDXM25F3V1B9 / 2MXM40N2V1B | FDXM25F3V1B9 / FDXM35F3V1B9 / 2MXM40N2V1B | FDXM25F3V1B9 / FDXM25F3V1B9 / 2MXM50N2V1B | FDXM25F3V1B9 / FDXM35F3V1B9 / 2MXM50N2V1B | FDXM25F3V1B9 / FDXM50F3V1B9 / 2MXM50N2V1B | FDXM35F3V1B9 / FDXM35F3V1B9 / 2MXM50N2V1B | FDXM35F3V1B9 / FDXM50F3V1B9 / 2MXM50N2V1B | ||||
|---|---|---|---|---|---|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 4.00 | 4.00 | 5.00 | 5.00 | 5.00 | 5.00 | 5.00 | |
| Space cooling | SEER | 6.28 | 6.16 | 6.21 | 6.24 | 6.51 | 6.41 | 6.40 | ||
| Annual energy consumption | kWh/a | 223 | 228 | 282 | 281 | 269 | 273 | 274 | ||
| Capacity | Pdesign | kW | 4.00 | 4.00 | 5.00 | 5.00 | 5.00 | 5.00 | 5.00 | |
| Energy efficiency class | A++ | A++ | A++ | A++ | A++ | A++ | A++ | |||
| Space heating (Average climate) | Capacity | Pdesign | kW | 3.20 | 3.20 | 4.20 | 4.20 | 4.20 | 4.20 | 4.20 |
| SCOP/A | 4.01 | 4.05 | 3.78 | 3.79 | 3.86 | 3.82 | 3.89 | |||
| Energy efficiency class | A+ | A+ | A | A | A | A | A | |||
| Pdh Heating capacity at -10° | kW | 2.61 | 2.62 | 3.42 | 3.43 | 3.55 | 3.44 | 3.57 | ||
| Annual energy consumption | kWh/a | 1,117 | 1,106 | 1,555 | 1,550 | 1,523 | 1,538 | 1,509 | ||
| Nominal efficiency | Annual energy consumption | kWh | 563 | 556 | 779 | 769 | 712 | 760 | 704 | |
| EER | 3.55 | 3.60 | 3.21 | 3.25 | 3.51 | 3.29 | 3.55 | |||
| COP | 4.13 | 4.17 | 3.66 | 3.64 | 3.61 | 3.62 | 3.61 | |||
| Energy labeling Directive | Cooling | A | A | A | A | A | A | A | ||
| Heating | A | A | A | A | A | A | A | |||
| Heating capacity | Nom. | kW | 4.20 | 4.20 | 5.60 | 5.60 | 5.60 | 5.60 | 5.60 | |
| Notes | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | |||
| (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||
| (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | ||||
| (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | ||||