FFA50A2VEB / RXS50L2V1B |
FFA60A2VEB / RXS60L2V1B |
Cooling capacity
|
Nom.
|
kW
|
5.00
|
5.70
|
Space cooling
|
SEER
|
|
5.93
|
5.71
|
|
Annual energy consumption
|
kWh/a
|
295
|
349
|
|
Capacity
|
Pdesign
|
kW
|
5.00
|
5.70
|
|
Energy efficiency class
|
|
A+
|
A+
|
Space heating (Average climate)
|
Capacity
|
Pdesign
|
kW
|
3.84
|
3.96
|
|
SCOP/A
|
|
3.90
|
4.04
|
|
Energy efficiency class
|
|
A
|
A+
|
|
Annual energy consumption
|
kWh/a
|
1,378
|
1,373
|
Piping connections
|
Liquid
|
OD
|
mm
|
6.35
|
6.35
|
|
Gas
|
OD
|
mm
|
12.70
|
12.70
|
|
Drain
|
OD
|
mm
|
VP20 (External dia.26, Internal dia. 20)
|
VP20 (External dia.26, Internal dia. 20)
|
Nominal efficiency
|
EER
|
|
3.21
|
3.02
|
|
Annual energy consumption
|
kWh
|
780
|
945
|
|
COP
|
|
3.49
|
3.41
|
|
Energy labeling Directive
|
Cooling
|
|
A
|
B
|
|
|
Heating
|
|
B
|
B
|
Heating capacity
|
Nom.
|
kW
|
5.80
|
7.00
|
Notes
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
|
(3) - See separate drawing for operation range
|
(3) - See separate drawing for operation range
|
|
(4) - See separate drawing for electrical data
|
(4) - See separate drawing for electrical data
|