Specifications Table for FTXA-BT / RXA-B8

FTXA42B2V1BT / RXA42B5V1B8
Cooling capacity Min. kW 1.7
  Nom. kW 4.2
  Max. kW 5
Heating capacity Min. kW 1.7
  Nom. kW 5.4
  Max. kW 6
Nominal efficiency EER   3.99
  COP   4.12
  Annual energy consumption kWh 526
  Energy labeling Directive Cooling   A
    Heating   A
Space cooling Energy efficiency class   A++
  Capacity Pdesign kW 4.2
  SEER   7.5
  Annual energy consumption kWh/a 196
Space heating (Average climate) Energy efficiency class   A++
  Capacity Pdesign kW 3.8
  SCOP/A   4.6
  Pdh Heating capacity at -10° kW 3.04
  Annual energy consumption kWh/a 1156
Energy Efficiency Range A+++ ~ D
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for operation range