Specifications Table for FTXJ-MW / 3MXM-N

FTXJ20MV1BW / FTXJ20MV1BW / 3MXM40N2V1B FTXJ20MV1BW / FTXJ20MV1BW / FTXJ20MV1BW / 3MXM40N2V1B FTXJ20MV1BW / FTXJ20MV1BW / 3MXM52N2V1B FTXJ20MV1BW / FTXJ20MV1BW / FTXJ20MV1BW / 3MXM52N2V1B FTXJ20MV1BW / FTXJ20MV1BW / 3MXM68N2V1B FTXJ20MV1BW / FTXJ20MV1BW / FTXJ20MV1BW / 3MXM68N2V1B
Cooling capacity Nom. kW 4.00 4.00 4.00 5.20 4.00 6.00
Space cooling SEER   7.62 7.46 7.72 7.70 5.42 6.23
  Annual energy consumption kWh/a 164 188 182 237 258 337
  Capacity Pdesign kW 4.00 4.00 4.00 5.20 4.00 6.00
  Energy efficiency class   A++ A++ A++ A++ A A++
Space heating (Average climate) Capacity Pdesign kW 4.80 5.00 4.80 5.00 3.20 5.30
  SCOP/A   4.11 4.18 4.11 4.18 3.87 4.00
  Energy efficiency class   A+ A+ A+ A+ A A+
  Pdh Heating capacity at -10° kW 3.58 1.00 1.0 1.0 2.80 4.13
  Annual energy consumption kWh/a 1,632 1,672 1,632 1,672 1,157 1,852
Nominal efficiency Annual energy consumption kWh 482 467 471 593 457 787
  EER   4.15 4.28 4.25 4.38 4.38 3.81
  COP   3.95 4.32 4.05 4.42 4.04 3.88
  Energy labeling Directive Cooling   A A A A A A
    Heating   A A A A A A
Heating capacity Nom. kW 4.60 4.60 6.80 6.80 6.50 7.80
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for operation range
  (4) - See separate drawing for electrical data