| FTXM25B2V1B / RXM25A5V1B9 | FTXM25B5V1B / RXM25A5V1B9 | FTXM35B2V1B / RXM35A5V1B9 | FTXM35B5V1B / RXM35A5V1B9 | FTXM50B2V1B / RXM50A5V1B9 | FTXM50B5V1B / RXM50A5V1B9 | ||||
|---|---|---|---|---|---|---|---|---|---|
| Cooling capacity | Min. | kW | 0.90 | 0.90 | 0.90 | 0.90 | 1.70 | 1.70 | |
| Nom. | kW | 2.50 | 2.50 | 3.50 | 3.50 | 5.00 | 5.00 | ||
| Max. | kW | 3.80 | 3.80 | 4.40 | 4.40 | 5.30 | 5.30 | ||
| Heating capacity | Min. | kW | 0.80 | 0.80 | 0.80 | 0.80 | 1.70 | 1.70 | |
| Nom. | kW | 2.80 | 2.80 | 4.00 | 4.00 | 5.80 | 5.80 | ||
| Max. | kW | 5.00 | 5.00 | 5.50 | 5.50 | 6.50 | 6.50 | ||
| Nominal efficiency | EER | 5.20 | 5.20 | 4.63 | 4.63 | 3.68 | 3.68 | ||
| COP | 5.00 | 5.00 | 4.55 | 4.55 | 3.95 | 3.95 | |||
| Annual energy consumption | kWh | 240 | 240 | 378 | 378 | 679 | 679 | ||
| Energy labeling Directive | Cooling | A | A | A | A | A | A | ||
| Heating | A | A | A | A | A | A | |||
| Space cooling | Energy efficiency class | A+++ | A+++ | A+++ | A+++ | A++ | A++ | ||
| Capacity | Pdesign | kW | 2.50 | 2.50 | 3.50 | 3.50 | 5.00 | 5.00 | |
| SEER | 9.47 | 9.47 | 9.25 | 9.25 | 7.80 | 7.80 | |||
| Annual energy consumption | kWh/a | 92 | 92 | 132 | 132 | 224 | 224 | ||
| Space heating (Average climate) | Energy efficiency class | A+++ | A+++ | A+++ | A+++ | A++ | A++ | ||
| Capacity | Pdesign | kW | 2.40 | 2.40 | 2.50 | 2.50 | 4.50 | 4.50 | |
| SCOP/A | 5.20 | 5.20 | 5.20 | 5.20 | 4.80 | 4.80 | |||
| Pdh Heating capacity at -10° | kW | 2.40 | 2.40 | 2.50 | 2.50 | 4.50 | 4.50 | ||
| Annual energy consumption | kWh/a | 647 | 647 | 673 | 673 | 1312 | 1312 | ||
| Energy Efficiency Range | A+++ ~ D | A+++ ~ D | A+++ ~ D | A+++ ~ D | A+++ ~ D | A+++ ~ D | |||
| Notes | (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | |||
| (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||
| (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | ||||
| (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | ||||