LREN8A7Y1B LREN10A7Y1B LREN12A7Y1B
Refrigerating capacity Low temperature Nom. kW 11.2 (3) 13.5 (3) 15.5 (3)
  Medium temperature Nom. kW 19.8 (4) 23.1 (4) 26.3 (4)
Power input Low temperature Nom. kW 11.6 (3) 14.1 (3) 16.9 (3)
  Medium temperature Nom. kW 10.7 (4) 13.2 (4) 15.5 (4)
COP Low temperature Nom.   0.97 (3) 0.96 (3) 0.92 (3)
  Medium temperature Nom.   1.86 (4) 1.75 (4) 1.69 (4)
Casing Colour   Ivory white Ivory white Ivory white
Dimensions Unit Height mm 1,680 1,680 1,680
    Width mm 1,930 1,930 1,930
    Depth mm 765 765 765
Weight Unit kg 547 547 547
Fan Type   Propeller fan Propeller fan Propeller fan
  Quantity   3 3 3
  Air flow rate Cooling Nom. m³/min 285 (6) 285 (6) 315 (6)
Fan motor Output W 750 750 750
  Drive   Direct drive Direct drive Direct drive
Heat exchanger Type   Cross fin coil (waffle louver fins and Hi-X tubes) Cross fin coil (waffle louver fins and Hi-X tubes) Cross fin coil (waffle louver fins and Hi-X tubes)
Refrigerant Type   R744 (CO2) R744 (CO2) R744 (CO2)
  GWP   1.0 1.0 1.0
  Charge kg 0.00 (7) 0.00 (7) 0.00 (7)
Standard Accessories Installation manual 1 1 1
  Operation manual 1 1 1
  Declaration of conformity 1 1 1
  General safety precautions 1 1 1
  Auxiliary piping set 1 1 1
  Safety valve pipe 1 1 1
  Safety valve 1 1 1
  Stop valve body insulation 1 1 1
  Stop valve cap insulation 1 1 1
Power supply Phase   3N~ 3N~ 3N~
  Frequency Hz 50 50 50
  Voltage V 380-415 380-415 380-415
Notes (1) - Minimum load of each individual refrigeration indoor unit: 3 KW (for Medium Temperature Operation) (1) - Minimum load of each individual refrigeration indoor unit: 3 KW (for Medium Temperature Operation) (1) - Minimum load of each individual refrigeration indoor unit: 3 KW (for Medium Temperature Operation)
  (2) - Minimum load of each individual refrigeration indoor unit: 2 KW (for Low Temperature Operation). (2) - Minimum load of each individual refrigeration indoor unit: 2 KW (for Low Temperature Operation). (2) - Minimum load of each individual refrigeration indoor unit: 2 KW (for Low Temperature Operation).
  (3) - Rated conditions: saturation temperature equivalent to suction pressure: -35°C (LT),outdoor temp. 32°C, Suction SH 10K (3) - Rated conditions: saturation temperature equivalent to suction pressure: -35°C (LT),outdoor temp. 32°C, Suction SH 10K (3) - Rated conditions: saturation temperature equivalent to suction pressure: -35°C (LT),outdoor temp. 32°C, Suction SH 10K
  (4) - Rated conditions: saturation temperature equivalent to suction pressure: -10°C (MT), outdoor temp. 32°C, Suction SH 10K (4) - Rated conditions: saturation temperature equivalent to suction pressure: -10°C (MT), outdoor temp. 32°C, Suction SH 10K (4) - Rated conditions: saturation temperature equivalent to suction pressure: -10°C (MT), outdoor temp. 32°C, Suction SH 10K
  (5) - Every compressor equipped with 1 accumulator of 0,909 liters. (5) - Every compressor equipped with 1 accumulator of 0,909 liters. (5) - Every compressor equipped with 1 accumulator of 0,909 liters.
  (6) - Outdoor Unit Total Airflow (6) - Outdoor Unit Total Airflow (6) - Outdoor Unit Total Airflow
  (7) - The unit is not pre-charged. A minimal rest charge is present related to factory quality inspection (7) - The unit is not pre-charged. A minimal rest charge is present related to factory quality inspection (7) - The unit is not pre-charged. A minimal rest charge is present related to factory quality inspection
  (8) - Compressor 1 (8) - Compressor 1 (8) - Compressor 1
  (9) - Compressor 2 (9) - Compressor 2 (9) - Compressor 2
  (10) - Compressor 3 (10) - Compressor 3 (10) - Compressor 3
  (11) - Factory charge of unit (11) - Factory charge of unit (11) - Factory charge of unit
  (12) - Sound pressure data: measured at 1m in front of unit, at 1.5m height. Nominal operation condition – Medium evaporation temperature (MT) (12) - Sound pressure data: measured at 1m in front of unit, at 1.5m height. Nominal operation condition – Medium evaporation temperature (MT) (12) - Sound pressure data: measured at 1m in front of unit, at 1.5m height. Nominal operation condition – Medium evaporation temperature (MT)
  (13) - For MT (Medium Temperature) Operation (13) - For MT (Medium Temperature) Operation (13) - For MT (Medium Temperature) Operation
  (14) - For LT (Low Temperature) Operation (14) - For LT (Low Temperature) Operation (14) - For LT (Low Temperature) Operation
  (15) - Compressor 1: 2Y190CPCY1P#C; Compressor 2: 2Y190CPCY1P#C; Compressor 3: 2Y190CPDY1P#C (15) - Compressor 1: 2Y190CPCY1P#C; Compressor 2: 2Y190CPCY1P#C; Compressor 3: 2Y190CPDY1P#C (15) - Compressor 1: 2Y190CPCY1P#C; Compressor 2: 2Y190CPCY1P#C; Compressor 3: 2Y190CPDY1P#C
  (16) - Only K65 (or equivalent) with D.P. 90 bar is allowed to use for refrigeration piping. (16) - Only K65 (or equivalent) with D.P. 90 bar is allowed to use for refrigeration piping. (16) - Only K65 (or equivalent) with D.P. 90 bar is allowed to use for refrigeration piping.
  (17) - For all the LRNUN5A7Y1 specifications, please refer to the related MDM drawing (17) - For all the LRNUN5A7Y1 specifications, please refer to the related MDM drawing (17) - For all the LRNUN5A7Y1 specifications, please refer to the related MDM drawing