Specifications Table for RDXYQ-T

RDXYQ5T7V1B RDXYQ8T7V1B
Sound pressure level Cooling Nom. dBA   54.0 (5)
Standard Accessories Installation and operation manual 1 1
  Drain hose 1 1
  Screws 1 1
  Tie-wraps 1 1
  Hose band 1 1
Weight Unit kg   103
Refrigerant Type     R-410A
Piping connections Drain OD mm   32
Sound power level Cooling Nom. dBA   81.0 (4)
Dimensions Unit Width mm   1,456
    Depth mm   1,044
    Height mm   397
  Ducting Height mm   298
    Width mm   1,196
Power supply Phase     1N~
  Name     V1
  Frequency Hz   50
  Voltage V   220-240
Notes (1) - Sound power level is an absolute value that a sound source generates. (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m
  (2) - Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings. (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m
  (3) - RLA is based on following conditions: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB (3) - Actual number of units depends on the indoor unit type (VRV DX indoor, etc.) and the connection ratio restriction for the system (being; 50% ≤ CR ≤ 130%).
  (4) - MCA must be used to select the correct field wiring size. The MCA can be regarded as the maximum running current. (4) - Sound power level is an absolute value that a sound source generates.
  (5) - MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). (5) - Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings.
  (6) - TOCA means the total value of each OC set. (6) - Refer to refrigerant pipe selection or installation manual
  (7) - FLA means the nominal running current of the fan (7) - RLA is based on following conditions: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB
    (8) - MSC means the maximum current during start up of the compressor. This unit uses only inverter compressors. Starting current is always ≤ max. running current.
    (9) - In accordance with EN/IEC 61000-3-12, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply wih Ssc ≥ minimum Ssc value
    (10) - MCA must be used to select the correct field wiring size. The MCA can be regarded as the maximum running current.
    (11) - MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker).
    (12) - TOCA means the total value of each OC set.
    (13) - FLA means the nominal running current of the fan
    (14) - Maximum allowable voltage range variation between phases is 2%.
    (15) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
    (16) - Sound values are measured in a semi-anechoic room.
    (17) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase
    (18) - Ssc: Short-circuit power
    (19) - For detailed contents of standard accessories, see installation/operation manual
Dimensions Unit Height mm 397
    Width mm 1456
    Depth mm 1044
  Ducting Height mm 298
    Width mm 1196
Weight Unit kg 97
Sound power level Cooling Nom. dBA 77.0 (4)
Sound pressure level Cooling Nom. dBA 47.0 (5)
Power supply Frequency Hz 50