| RZAG71N7V1B | RZAG71N2V1B | RZAG100N7V1B | RZAG100N2V1B | RZAG125N7V1B | RZAG125N2V1B | RZAG140N7V1B | RZAG140N2V1B | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dimensions | Unit | Height | mm | 870 | 870 | 870 | 870 | 870 | 870 | 870 | 870 | |
| Width | mm | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | |||
| Depth | mm | 460 | 460 | 460 | 460 | 460 | 460 | 460 | 460 | |||
| Weight | Unit | kg | 81 | 81 | 85 | 85 | 95 | 95 | 95 | 95 | ||
| Compressor | Type | Hermetically sealed swing compressor | Hermetically sealed swing compressor | Hermetically sealed swing compressor | Hermetically sealed swing compressor | Hermetically sealed swing compressor | Hermetically sealed swing compressor | Hermetically sealed swing compressor | Hermetically sealed swing compressor | |||
| Operation range | Cooling | Ambient | Min. | °CDB | -20 | -20 | -20 | -20 | -20 | -20 | -20 | -20 |
| Max. | °CDB | 52 | 52 | 52 | 52 | 52 | 52 | 52 | 52 | |||
| Heating | Ambient | Min. | °CWB | -20 | -20 | -20 | -20 | -20 | -20 | -20 | -20 | |
| Max. | °CWB | 18 | 18 | 18 | 18 | 18 | 18 | 18 | 18 | |||
| Sound power level | Cooling | dBA | 64 | 64 | 66 | 66 | 69 | 69 | 70 | 70 | ||
| Heating | dBA | 68 (1) | 68 (1) | 71 (1) | 71 (1) | |||||||
| Sound pressure level | Cooling | Nom. | dBA | 46 | 46 | 47 | 47 | 49 | 49 | 50 | 50 | |
| Heating | Nom. | dBA | 48 | 48 | 50 | 50 | 52 | 52 | 52 | 52 | ||
| Refrigerant | Type | R-32 | R-32 | R-32 | R-32 | R-32 | R-32 | R-32 | R-32 | |||
| Charge | kg | 3.2 | 3.20 | 3.2 | 3.20 | 3.7 | 3.70 | 3.7 | 3.70 | |||
| GWP | 675 | 675 | 675 | 675 | 675 | 675 | 675 | 675 | ||||
| Charge | tCO2Eq | 2.16 | 2.16 | 2.16 | 2.16 | 2.5 | 2.50 | 2.5 | 2.50 | |||
| Piping connections | Liquid | OD | mm | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | |
| Gas | OD | mm | 15.9 | 15.9 | 15.9 | 15.9 | 15.9 | 15.9 | 15.9 | 15.9 | ||
| Piping length | OU - IU | Max. | m | 55 | 55 | 85 | 85 | 85 | 85 | 85 | 85 | |
| System | Equivalent | m | 75 | 75 | 100 | 100 | 100 | 100 | 100 | 100 | ||
| Chargeless | m | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | |||
| Additional refrigerant charge | kg/m | See installation manual | See installation manual | See installation manual | See installation manual | See installation manual | See installation manual | See installation manual | See installation manual | |||
| Level difference | IU - OU | Max. | m | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | |
| IU - IU | Max. | m | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | ||
| Standard Accessories | Installation manual | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |||
| Refrigerant label for F-gas regulation | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | ||||
| General safety precautions | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | ||||
| Peel off F-gas label | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | ||||
| Tie-wraps | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | ||||
| Power supply | Phase | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | |||
| Frequency | Hz | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | |||
| Voltage | V | 220-240 | 220-240 | 220-240 | 220-240 | 220-240 | 220-240 | 220-240 | 220-240 | |||
| Current - 50Hz | Maximum fuse amps (MFA) | A | 20 | 20 | 32 | 32 | 32 | 32 | 32 | 32 | ||
| Notes | (1) - According to ENER Lot 21 | (1) - According to ENER Lot 21 | (1) - According to ENER Lot 21 | (1) - According to ENER Lot 21 | ||||||||