RHOB12AAV1H |
RHOB18AAV1H |
RHOB42AAV1H |
Gas |
Connection |
Diameter |
Mm |
15 |
15 |
15 |
|
NOx class |
|
5 |
6 |
6 |
|
NOx level (G20) |
mg/kWh |
|
44 |
53 |
Central heating |
Heat input Qn (net calorific value) |
Nom |
Min |
kW |
3.5 |
5.6 |
7.8 |
|
|
|
Max |
kW |
11.8 |
18.7 |
42.5 |
|
Heat input Qn (gross calorific value) |
Nom |
Min |
kW |
3.9 |
6.2 |
8.7 |
|
|
|
Max |
kW |
13.1 |
20.8 |
47.2 |
|
Efficiency |
Net calorific value |
% |
109 |
|
|
Space heating |
General |
Seasonal space heating eff. class |
|
A |
A |
A |
Heat losses |
Stand-by boiler Ps |
kW |
0.038 |
|
|
Supply air |
Concentric |
|
Yes |
60/100 |
60/100 |
Flue gas |
Mass flow (G20) |
Max |
kg/h |
5.5 |
8.7 |
19.7 |
|
Mass flow (G25) |
Max |
kg/h |
5.5 |
8.7 |
19.7 |
|
Mass flow (G31) |
Max |
kg/h |
|
8.5 |
19.4 |
Casing |
Colour |
|
White - RAL9010 |
RAL9010 |
RAL9010 |
|
Material |
|
Precoated sheet metal |
Steel |
Steel |
Dimensions |
Unit |
Height |
Casing |
Mm |
590 |
590 |
710 |
Notes |
(1) - Setpoint 40°C |
(1) - Setpoint 40°C |
(1) - Setpoint 40°C |
|
(2) - Setpoint 60°C |
(2) - Setpoint 60°C |
(2) - Setpoint 60°C |
|
(3) - Gas supply pressure Germany & France: installer can modify Gas Valve. (Change setting from G20 to G25). |
(3) - Gas supply pressure Germany & France: installer can modify Gas Valve. (Change setting from G20 to G25). |
(3) - Gas supply pressure Germany & France: installer can modify Gas Valve. (Change setting from G20 to G25). |
|
(4) - Gas supply pressure Belgium: Installer cannot modify Gas Valve. (G25 will be burned with G20 setting) = 18% lower capacity. |
(4) - Gas supply pressure Belgium: Installer cannot modify Gas Valve. (G25 will be burned with G20 setting) = 18% lower capacity. |