EHBX11CB3V / ERHQ011BAV3 EHBX11CB9W / ERHQ011BAV3 EHBX16CB3V / ERHQ014BAV3 EHBX16CB9W / ERHQ014BAV3 EHBX16CB3V / ERHQ016BAV3 EHBX16CB9W / ERHQ016BAV3
Calefacción de espacios general Unidad aire-agua Flujo nominal (exterior) m³/h 5,400 5,400 5,400 5,400 5,400 5,400
  Otros Psb (modo de espera) kW 0.055 0.055 0.055 0.055 0.055 0.055
    Poff (modo de desconexión) kW 0.055 0.055 0.055 0.055 0.055 0.055
    Pto (termostato desconectado) kW 0.057 0.057 0.057 0.057 0.057 0.057
    Pck (modo de calentador del cárter) kW 0.055 0.055 0.055 0.055 0.055 0.055
    Space heating general-=-Other-=-Cdh degradation heating 1.00 1.00 1.00 1.00 1.00 1.00
  Calentador suplementario integrado Psup kW 3.00 9.00 3.00 9.00 3.00 9.00
    Emisión de NOx mg/kWh 0.00 0.00 0.00 0.00 0.00 0.00
Intercambiador de calor del lado del agua Caudal de agua Refrigeración Nom. l/min 28.7 (3), 39.8 (4) 28.7 (3), 39.8 (4) 35.8 (3), 49.6 (4) 35.8 (3), 49.6 (4) 37.6 (3), 51.0 (4) 37.6 (3), 51.0 (4)
    Calefacción Nom. l/min 32.1 (5), 29.5 (6) 32.1 (5), 29.5 (6) 40.1 (5), 37.6 (6) 40.1 (5), 37.6 (6) 45.9 (5), 43.6 (6) 45.9 (5), 43.6 (6)
Bomba Unidad de presión estática externa nominal Calefacción kPa 37.0 (5), 44.0 (6) 37.0 (5), 44.0 (6) 54.0 (5), 61.0 (6) 54.0 (5), 61.0 (6) 33.0 (5), 42.0 (6) 33.0 (5), 42.0 (6)
    Refrigeración kPa 46.0 (3), 14.0 (4) 46.0 (3), 14.0 (4) 65.0 (3), 15.0 (4) 65.0 (3), 15.0 (4) 61.0 (3), 8.00 (4) 61.0 (3), 8.00 (4)
Calefacción de espacios Temp. agua salida, clima medio 35°C Condición A (-7°CBS/-8°CBH) PERd % 111 111 103 103 98.4 98.4
      Pdh kW 6.68 6.68 7.88 7.88 8.80 8.80
      Space heating-=-Average climate water outlet 35°C-=-A Condition (-7°CDB/-8°CWB)-=-Copd 2.77 2.77 2.58 2.58 2.46 2.46
    Condición C (7°CBS/6°CBH) Pdh kW 3.88 3.88 4.85 4.85 5.54 5.54
      PERd % 135 135 174 174 191 191
      Space heating-=-Average climate water outlet 35°C-=-C Condition (7°CDB/6°CWB)-=-Copd 1.00 1.00 1.00 1.00 1.00 1.00
    Condición D (12°CBS/11°CBH) Pdh kW 4.10 4.10 5.08 5.08 5.72 5.72
      PERd % 136 136 186 186 208 208
      Space heating-=-Average climate water outlet 35°C-=-D Condition (12°CDB/11°CWB)-=-Copd 0.940 0.940 0.950 0.950 1.00 1.00
    Capac. supl. de salida calorífica nom. Psup (Tdesign -10°C) kW 4.97 4.97 6.43 6.43 7.41 7.41
    General Consumo energético anual kWh 7,323 7,323 8,520 8,520 9,622 9,622
      Consumo energético anual (GCV) Gj 26.4 26.4 30.7 30.7 34.6 34.6
      Ƞs (Efic. estac. de calef. de habitaciones) % 117 117 126 126 129 129
      Valor nominal P a -10°C kW 11.2 11.2 14.0 14.0 16.0 16.0
      Space heating-=-Average climate water outlet 35°C-=-General-=-Seasonal space heating eff class 2.99 2.99 3.23 3.23 3.29 3.29
    Condición B (2°CBS/1°CBH) Pdh kW 6.03 6.03 7.54 7.54 8.62 8.62
      PERd % 150 150 153 153 153 153
      Space heating-=-Average climate water outlet 35°C-=-B Condition (2°CDB/1°CWB)-=-Copd 1.00 1.00 1.00 1.00 1.00 1.00
    Tbiv (temperatura bivalente) Pdh kW 7.54 7.54 9.39 9.39 10.6 10.6
      PERd % 138 138 135 135 128 128
      Tbiv °C -1.00 -1.00 -1.00 -1.00 -1.00 -1.00
      Space heating-=-Average climate water outlet 35°C-=-Tbiv (bivalent temperature)-=-Copd 3.46 3.46 3.37 3.37 3.21 3.21
    Tol (límite de funcionamiento de Temp.) PERd % 102 102 98.4 98.4 94.4 94.4
      WTOL °C 35.0 35.0 35.0 35.0 35.0 35.0
      Pdh kW 6.23 6.23 7.57 7.57 8.59 8.59
      TOL °C -10.0 -10.0 -10.0 -10.0 -10.0 -10.0
      Space heating-=-Average climate water outlet 35°C-=-Tol (temperature operating limit)-=-Copd 2.55 2.55 2.46 2.46 2.36 2.36
  Salida de agua con clima cálido, 55°C General Consumo energético anual (GCV) Gj 9.72 9.72 11.3 11.3 11.7 11.7
      Pnominal a 2°C kW 6.99 6.99 8.73 8.73 9.19 9.19
      Ƞs (Efic. estac. de calef. de habitaciones) % 113 113 124 124 127 127
      Consumo energético anual kWh 2,699 2,699 3,141 3,141 3,255 3,255
  Temperatura del agua de salida en clima cálido 35°C General Pnominal a 2°C kW 7.86 7.86 9.72 9.72 10.9 10.9
      Ƞs (Efic. estac. de calef. de habitaciones) % 125 125 153 153 164 164
      Consumo energético anual kWh 2,760 2,760 2,792 2,792 2,942 2,942
      Consumo energético anual (GCV) Gj 9.94 9.94 10.1 10.1 10.6 10.6
  Temperatura del agua de salida en clima medio 55°C Condición A (-7°CBS/-8°CBH) PERd % 86.4 86.4 75.6 75.6 75.6 75.6
      Pdh kW 7.37 7.37 8.08 8.08 9.00 9.00
      Space heating-=-Average climate water outlet 55°C-=-A Condition (-7°CDB/-8°CWB)-=-Copd 1.00 1.00 1.00 1.00 1.00 1.00
    Tbiv (temperatura bivalente) Tbiv °C -5.00 -5.00 -3.00 -3.00 -3.00 -3.00
      Pdh kW 7.62 7.62 9.32 9.32 10.0 10.0
      PERd % 91.6 91.6 95.2 95.2 94.4 94.4
      Space heating-=-Average climate water outlet 55°C-=-Tbiv (bivalent temperature)-=-Copd 2.29 2.29 2.38 2.38 2.36 2.36
    Tol (límite de temperatura de funcionamiento) TOL °C -7.00 -7.00 -7.00 -7.00 -7.00 -7.00
      Pdh kW 7.37 7.37 8.08 8.08 9.00 9.00
      PERd % 86.4 86.4 75.6 75.6 75.6 75.6
      WTOL °C 52.0 52.0 52.0 52.0 52.0 52.0
      Space heating-=-Average climate water outlet 55°C-=-Tol (temperature operating limit)-=-Copd 2.16 2.16 1.89 1.89 1.89 1.89
    General Consumo energético anual (GCV) Gj 23.2 23.2 30.9 30.9 32.6 32.6
      Eficiencia de calefacción de espacios estacional % 112 112 110 110 114 114
      Consumo energético anual kWh 6,451 6,451 8,583 8,583 9,067 9,067
      Pnominal a -10°C kW 9.53 9.53 12.3 12.3 13.4 13.4
      Space heating-=-Average climate water outlet 55°C-=-General-=-Seasonal space heating eff class 2.86 2.86 2.82 2.82 2.92 2.92
    Condición B (2°CBS/1°CBH) Pdh kW 5.27 5.27 6.50 6.50 7.50 7.50
      PERd % 126 126 124 124 125 125
      Space heating-=-Average climate water outlet 55°C-=-B Condition (2°CDB/1°CWB)-=-Copd 1.00 1.00 1.00 1.00 0.980 0.980
    Condición C (7°CBS/6°CBH) Pdh kW 4.43 4.43 4.43 4.43 4.90 4.90
      PERd % 156 156 156 156 178 178
      Space heating-=-Average climate water outlet 55°C-=-C Condition (7°CDB/6°CWB)-=-Copd 0.950 0.950 0.950 0.950 0.950 0.950
    Condición D (12°CBS/11°CBH) PERd % 222 222 222 222 225 225
      Pdh kW 5.32 5.32 5.32 5.32 5.30 5.30
      Space heating-=-Average climate water outlet 55°C-=-D Condition (12°CDB/11°CWB)-=-Copd 0.940 0.940 0.940 0.940 0.940 0.940
    Capacidad supl. potencia calorífica nom. Psup (Tdesign -10°C) kW 2.16 2.16 4.22 4.22 4.40 4.40
Capacidad de refrigeración Nom. kW 13.9 (1), 10.0 (2) 13.9 (1), 10.0 (2) 17.3 (1), 12.5 (2) 17.3 (1), 12.5 (2) 17.8 (1), 13.1 (2) 17.8 (1), 13.1 (2)
Capacidad de calefacción Nom. kW 11.2 (1), 10.3 (2) 11.2 (1), 10.3 (2) 14.0 (1), 13.1 (2) 14.0 (1), 13.1 (2) 16.0 (1), 15.2 (2) 16.0 (1), 15.2 (2)
General LW(A) Nivel de potencia sonora (conforme a EN14825) Interior dB(A) 41.0 41.0 44.0 44.0 44.0 44.0
  Información sobre el proveedor/fabricante Nombre y dirección Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V.
  Descripción del producto General-=-Product description-=-Low temperature heat pump No No No No No No
LW(A) Nivel de potencia sonora (conforme a EN14825) Exterior dB(A) 64.0 64.0 64.0 64.0 66.0 66.0
Consumo Calefacción Nom. kW 2.55 (1), 3.17 (2) 2.55 (1), 3.17 (2) 3.26 (1), 4.04 (2) 3.26 (1), 4.04 (2) 3.92 (1), 4.75 (2) 3.92 (1), 4.75 (2)
  Refrigeración Nom. kW 3.86 (1), 3.69 (2) 3.86 (1), 3.69 (2) 5.86 (1), 5.69 (2) 5.86 (1), 5.69 (2) 6.87 (1), 5.95 (2) 6.87 (1), 5.95 (2)
Sound condition ecodesign and energy label 3.60 (1), 2.71 (2) 3.60 (1), 2.71 (2) 2.95 (1), 2.32 (2) 2.95 (1), 2.32 (2) 2.59 (1), 2.20 (2) 2.59 (1), 2.20 (2)
Notas Condición 1: refrigeración Ta 35°C - LWE 18℃ (DT = 5°C); calefacción Ta BS/BH 7°C/6°C - LWC 35°C (DT = 5°C) Condición 1: refrigeración Ta 35°C - LWE 18℃ (DT = 5°C); calefacción Ta BS/BH 7°C/6°C - LWC 35°C (DT = 5°C) Condición 1: refrigeración Ta 35°C - LWE 18℃ (DT = 5°C); calefacción Ta BS/BH 7°C/6°C - LWC 35°C (DT = 5°C) Condición 1: refrigeración Ta 35°C - LWE 18℃ (DT = 5°C); calefacción Ta BS/BH 7°C/6°C - LWC 35°C (DT = 5°C) Condición 1: refrigeración Ta 35°C - LWE 18℃ (DT = 5°C); calefacción Ta BS/BH 7°C/6°C - LWC 35°C (DT = 5°C) Condición 1: refrigeración Ta 35°C - LWE 18℃ (DT = 5°C); calefacción Ta BS/BH 7°C/6°C - LWC 35°C (DT = 5°C)
  Condición 2: refrigeración Ta 35°C - LWE 7℃ (DT = 5°C); calefacción Ta BS/BH 7°C/6°C - LWC 45℃ (DT = 5°C) Condición 2: refrigeración Ta 35°C - LWE 7℃ (DT = 5°C); calefacción Ta BS/BH 7°C/6°C - LWC 45℃ (DT = 5°C) Condición 2: refrigeración Ta 35°C - LWE 7℃ (DT = 5°C); calefacción Ta BS/BH 7°C/6°C - LWC 45℃ (DT = 5°C) Condición 2: refrigeración Ta 35°C - LWE 7℃ (DT = 5°C); calefacción Ta BS/BH 7°C/6°C - LWC 45℃ (DT = 5°C) Condición 2: refrigeración Ta 35°C - LWE 7℃ (DT = 5°C); calefacción Ta BS/BH 7°C/6°C - LWC 45℃ (DT = 5°C) Condición 2: refrigeración Ta 35°C - LWE 7℃ (DT = 5°C); calefacción Ta BS/BH 7°C/6°C - LWC 45℃ (DT = 5°C)
  T amb 35°C - LWE 7°C (DT = 5°C) T amb 35°C - LWE 7°C (DT = 5°C) T amb 35°C - LWE 7°C (DT = 5°C) T amb 35°C - LWE 7°C (DT = 5°C) T amb 35°C - LWE 7°C (DT = 5°C) T amb 35°C - LWE 7°C (DT = 5°C)
  T amb 35°C - LWE 18℃ (DT = 5°C) T amb 35°C - LWE 18℃ (DT = 5°C) T amb 35°C - LWE 18℃ (DT = 5°C) T amb 35°C - LWE 18℃ (DT = 5°C) T amb 35°C - LWE 18℃ (DT = 5°C) T amb 35°C - LWE 18℃ (DT = 5°C)
  BS/BH 7°C/6°C-LWC 35°C(DT=5°C) BS/BH 7°C/6°C-LWC 35°C(DT=5°C) BS/BH 7°C/6°C-LWC 35°C(DT=5°C) BS/BH 7°C/6°C-LWC 35°C(DT=5°C) BS/BH 7°C/6°C-LWC 35°C(DT=5°C) BS/BH 7°C/6°C-LWC 35°C(DT=5°C)
  BS/BH 7°C/6°C-LWC 45℃(DT=5°C) BS/BH 7°C/6°C-LWC 45℃(DT=5°C) BS/BH 7°C/6°C-LWC 45℃(DT=5°C) BS/BH 7°C/6°C-LWC 45℃(DT=5°C) BS/BH 7°C/6°C-LWC 45℃(DT=5°C) BS/BH 7°C/6°C-LWC 45℃(DT=5°C)
  Contiene gases fluorados de efecto invernadero Contiene gases fluorados de efecto invernadero Contiene gases fluorados de efecto invernadero Contiene gases fluorados de efecto invernadero Contiene gases fluorados de efecto invernadero Contiene gases fluorados de efecto invernadero