FAQ71CVEB / RZQSG71L3V1B FAQ100CVEB / RZQSG100L9V1B
Poff (modo apagado) W 0.0 0.0
Refrigeración Psb (refrigeración en modo de espera) W 7.0 7.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25
Eficiencia estacional (conforme a EN14825) Refrigeración Pdesign kW 6.80 9.50
    Consumo energético anual kWh 393 593
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 6.05 5.61
    Condición D (20 ℃ - 27/19) Pdc kW 3.65 3.87
      consumo kW 0.32 0.38
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 11.32 10.39
    Condición C (25 ℃ - 27/19) consumo kW 0.42 0.60
      Pdc kW 3.52 4.50
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 8.32 7.56
    Condición A (35 °C - 27/19) consumo kW 2.12 3.16
      Pdc kW 6.80 9.50
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.21 3.01
    Condición B (30 ℃ - 27/19) Pdc kW 5.01 7.00
      consumo kW 1.28 2.04
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 3.93 3.44
  Calefacción (clima medio) Consumo energético anual kWh 2,155 2,378
    Pdesign kW 6.00 6.81
    Cap. calefacción reserva necesaria condiciones diseño kW 0.50 0.36
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A A+
    TBivalent Pdh (capacidad de calefacción declarada) kW 5.31 6.02
      Consumo kW   2.09
      Tbiv (temperatura bivalente) °C -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.16 2.89
    Condición C (7 ℃) Pdh (cap. de calefacción decl.) kW 2.84 2.97
      Consumo kW   0.49
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 5.76 6.13
    TOL Tol (límite de funcionamiento de temp.) °C -15 -15
      Pdh (capacidad de calefacción declarada) kW 5.82 7.15
      Consumo kW 3.29 4.00
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.77 1.79
    Condición A (-7℃) Pdh (cap. de calefacción decl.) kW 5.31 6.02
      Consumo kW   2.09
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.16 2.89
    Condición D (12 ℃) Pdh (cap. de calefacción decl.) kW 3.23 3.38
      Consumo kW   0.48
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 6.61 7.15
    Condición B (2 ℃) Consumo kW   1.27
      Pdh (cap. de calefacción decl.) kW 3.56 4.74
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.03 3.76
Capacidad de refrigeración Nom. kW 6.8 9.5
Pck (modo de calentador del cárter) W 0.0 0.0
Eficiencia nominal Consumo energético anual kWh 1,060 (0.000) 1,580 (0.000)
  Directiva de etiquetado de eficiencia energética Calefacción A B
  Nominal efficiency-=-Cop 3.21 3.01
Calefacción Psb (calefacción en modo de espera) W   7.0
  Heating-=-Heating cdh degradation heating 0.25 0.25
Capacidad de calefacción Nom. kW 7.5 10.8
Pto (Thermostat off) W 7.0 7.0
Consumo Refrigeración Nom. kW 2.12 3.16
  Calefacción Nom. kW 2.08 3.17
Estación fría incluida Sí Sí
Notas EER/COP conforme a Eurovent 2012, solo para uso fuera de la UE EER/COP conforme a Eurovent 2012, solo para uso fuera de la UE
  Eficiencia nominal: refrigeración a 35°/27° de carga nominal, calefacción a 7°/20° de carga nominal Eficiencia nominal: refrigeración a 35°/27° de carga nominal, calefacción a 7°/20° de carga nominal