| JEHSCU0200CM1 | JEHSCU0250CM1 | JEHSCU0300CM1 | |||||
|---|---|---|---|---|---|---|---|
| Capacidad de refrigeración | Temperatura media | R-407F | Nom. | kW | 3.33 | 3.82 | 4.63 |
| Capacidad de refrig. | Temperatura media | R-449A | Nom. | kW | 3.33 | 3.82 | 4.73 |
| Capacidad de refrigeración | Temperatura media | R-407A | Nom. | kW | 3.48 | 4.09 | |
| Capacidad de refrig. | Temperatura media | R-448A | Nom. | kW | 3.33 | 3.82 | 4.73 |
| Capacidad de refrigeración | Temperatura media | R-134a | Nom. | kW | 2.13 | ||
| Consumo | Temperatura media | R-407F | Nom. | kW | 1.74 | 2.09 | 2.65 |
| R-407A | Nom. | kW | 1.59 | 1.99 | |||
| R-448A | Nom. | kW | 1.65 | 1.98 | 2.56 | ||
| R-134a | Nom. | kW | 1.11 | ||||
| R-449A | Nom. | kW | 1.65 | 1.98 | 2.56 | ||
| COP | Temperatura media | R-448A | 2.02 | 1.93 | 1.85 | ||
| R-449A | 2.02 | 1.93 | 1.85 | ||||
| Temp. media | R-407F | 1.92 | 1.83 | 1.74 | |||
| R-134a | 1.92 | ||||||
| R-407A | 2.18 | 2.06 | |||||
| Parámetros a plena carga y temp. amb. 32 °C (punto A) | R-134a | Te -10°C | Capacidad de refrigeración nominal (PA) | kW | 2.13 | ||
| Consumo nominal (DA) | kW | 1.11 | |||||
| COP nominal (COPA) | 1.92 | ||||||
| R-407A | Te -10°C | Capacidad de refrigeración nominal (PA) | kW | 3.48 | 4.09 | ||
| Consumo nominal (DA) | kW | 1.59 | 1.99 | ||||
| COP nominal (COPA) | 2.18 | 2.06 | |||||
| R-407F | Te -10°C | Capacidad de refrigeración nominal (PA) | kW | 3.33 | 3.82 | 4.63 | |
| Consumo nominal (DA) | kW | 1.74 | 2.09 | 2.65 | |||
| COP nominal (COPA) | 1.92 | 1.83 | 1.74 | ||||
| Parámetros a plena carga y temp. ambiente 32 °C (punto A) | R-448A | Te -10°C | Capacidad de refrig. nominal (PA) | kW | 3.33 | 3.82 | 4.73 |
| Consumo nominal (DA) | kW | 1.65 | 1.98 | 2.56 | |||
| COP nominal (COPA) | 2.02 | 1.93 | 1.85 | ||||
| R-449A | Te -10°C | Capacidad de refrig. nominal (PA) | kW | 3.33 | 3.82 | 4.73 | |
| Consumo nominal (DA) | kW | 1.65 | 1.98 | 2.56 | |||
| COP nominal (COPA) | 2.02 | 1.93 | 1.85 | ||||
| Parámetros a plena carga y temp. amb. 25°C | R-134a | Te -10°C | COP declarado (COP2) | 2.21 | |||
| R-407A | Te -10°C | COP declarado (COP2) | 2.61 | 2.44 | |||
| R-407F | Te -10°C | COP declarado (COP2) | 2.46 | 2.33 | 2.21 | ||
| Parámetros a plena carga y temp. ambiente 25°C | R-448A | Te -10°C | Consumo (D2) | kW | 1.43 | 1.76 | 2.27 |
| COP declarado (COP2) | 2.53 | 2.32 | 2.23 | ||||
| R-449A | Te -10°C | Consumo (D2) | kW | 1.43 | 1.76 | 2.27 | |
| COP declarado (COP2) | 2.53 | 2.32 | 2.23 | ||||
| Parámetros a plena carga y temp. amb. 43 °C | R-134a | Te -10°C | COP declarado (COP3) | 1.42 | |||
| Parámetros a plena carga y temp. ambiente 43°C | R-448A | Te -10°C | COP declarado (COP3) | 1.31 | 1.36 | 1.31 | |
| R-449A | Te -10°C | COP declarado (COP3) | 1.31 | 1.36 | 1.31 | ||
| Ventilador | Tipo | Axial | Axial | Axial | |||
| Dimensiones | Unidad | Altura | mm | 662 | 662 | 662 | |
| Anchura | mm | 1101 | 1101 | 1101 | |||
| Profundidad | mm | 444 | 444 | 444 | |||
| Peso | Unidad | kg | 69.7 | 71.7 | 73.7 | ||
| Refrigerante | Tipo | R-134a | |||||
| Carcasa | Color | Gris claro | Gris claro | Gris claro | |||
| Refrigerante | GWP | 1430 | |||||
| Tipo 2 | R-407A | R-407A | |||||
| Tipo 3 | R-407F | R-407F | R-407F | ||||
| Tipo 5 | R-448A | R-448A | R-448A | ||||
| GWP Tipo 5 | 1387 | 1387 | 1387 | ||||
| GWP Tipo 2 | 2107 | 2107 | |||||
| GWP Tipo 3 | 1825 | 1825 | 1825 | ||||
| Alimentación eléctrica | Fase | 1~ | 1~ | 1~ | |||
| Frecuencia | Hz | 50 | 50 | 50 | |||
| Tensión | V | 230 | 230 | 230 | |||
| Notas | (1) - SRG 20°C, Ta=32°C, Te=-35°C | (1) - SRG 20°C, Ta=32°C, Te=-35°C | (1) - SRG 20°C, Ta=32°C, Te=-35°C | ||||
| (2) - El nivel de presión sonora se mide en una cámara anecoica a 10 m | (2) - El nivel de presión sonora se mide en una cámara anecoica a 10 m | (2) - El nivel de presión sonora se mide en una cámara anecoica a 10 m | |||||
| (3) - Su funcionamiento se basa en gases fluorados de efecto invernadero | (3) - Su funcionamiento se basa en gases fluorados de efecto invernadero | (3) - Su funcionamiento se basa en gases fluorados de efecto invernadero | |||||