| JEHSCU0600CM3 | JEHSCU0680CM3 | JEHSCU0800CM3 | JEHSCU1000CM3 | JEHSCU0360CM3 | JEHSCU0200CM3 | JEHSCU0250CM3 | JEHSCU0300CM3 | JEHSCU0350CM3 | JEHSCU0400CM3 | JEHSCU0500CM3 | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Capacidad de refrigeración | Temperatura media | R-407F | Nom. | kW | 9.59 | 12.90 | 5.73 | 3.33 | 3.94 | 4.58 | 6.75 | 8.18 | |||
| Capacidad de refrig. | Temperatura media | R-449A | Nom. | kW | 9.45 | 10.50 | 12.65 | 15.85 | 5.76 | 3.33 | 3.82 | 4.73 | 5.46 | 6.37 | 7.88 |
| Capacidad de refrigeración | Temperatura media | R-407A | Nom. | kW | 9.54 | 10.70 | 12.95 | 5.77 | 3.45 | 4.05 | 4.69 | 6.76 | 8.28 | ||
| Capacidad de refrig. | Temperatura media | R-448A | Nom. | kW | 9.45 | 10.50 | 12.65 | 15.85 | 5.76 | 3.33 | 3.82 | 4.73 | 5.46 | 6.37 | 7.88 |
| Capacidad de refrigeración | Temperatura media | R-134a | Nom. | kW | 8.21 | 10.75 | 3.8 | 2.24 | 3.48 | 4.37 | |||||
| Consumo | Temperatura media | R-407F | Nom. | kW | 5.03 | 6.13 | 2.91 | 1.77 | 2.15 | 2.71 | 3.21 | 4.36 | |||
| R-407A | Nom. | kW | 4.65 | 5.54 | 6.24 | 2.58 | 1.62 | 2.04 | 2.44 | 2.97 | 3.93 | ||||
| R-448A | Nom. | kW | 4.83 | 5.85 | 6.23 | 8.68 | 2.83 | 1.65 | 1.98 | 2.56 | 3.09 | 3.22 | 4.43 | ||
| R-134a | Nom. | kW | 3.74 | 4.86 | 1.61 | 1.02 | 1.68 | 1.85 | |||||||
| R-449A | Nom. | kW | 4.83 | 5.85 | 6.23 | 8.68 | 2.83 | 1.65 | 1.98 | 2.56 | 3.09 | 3.22 | 4.43 | ||
| COP | Temperatura media | R-448A | 1.96 | 1.79 | 2.03 | 1.83 | 2.04 | 2.02 | 1.93 | 1.85 | 1.77 | 1.98 | 1.78 | ||
| R-449A | 1.96 | 1.79 | 2.03 | 1.83 | 2.04 | 2.02 | 1.93 | 1.85 | 1.77 | 1.98 | 1.78 | ||||
| Temp. media | R-407F | 1.91 | 2.10 | 1.97 | 1.88 | 1.83 | 1.69 | 2.10 | 1.88 | ||||||
| R-134a | 2.19 | 2.21 | 2.36 | 2.19 | 2.08 | 2.36 | |||||||||
| R-407A | 2.05 | 1.93 | 2.08 | 2.24 | 2.12 | 1.99 | 1.92 | 2.28 | 2.11 | ||||||
| Consumo eléctrico anual Q | R-134a | Te -10°C | kWh/a | 16,256.53 | 19,586.43 | ||||||||||
| R-407A | Te -10°C | kWh/a | 18,407.87 | 22,239.63 | 25,490.84 | 10,186.80 | 10,972.69 | 15,847.87 | |||||||
| R-407F | Te -10°C | kWh/a | 18,902.83 | 26,882.45 | 10,932.85 | 11,873.19 | 16,401.48 | ||||||||
| R-448A | Te -10°C | kWh/a | 18,395.20 | 22,297.99 | 26,969.00 | 34,432.47 | 11,735.56 | 12,363.00 | 12,512.09 | 16,304.78 | |||||
| R-449A | Te -10°C | kWh/a | 18,395.20 | 22,297.99 | 26,969.00 | 34,432.47 | 11,735.56 | 12,363.00 | 12,512.09 | 16,304.78 | |||||
| Relación de rendimiento energético estacional SEPR | R-134a | Te -10°C | 3.10 | 3.37 | |||||||||||
| R-407A | Te -10°C | 3.19 | 2.96 | 3.12 | 3.48 | 3.79 | 3.21 | ||||||||
| R-407F | Te -10°C | 3.12 | 2.95 | 3.22 | 3.50 | 3.07 | |||||||||
| R-448A | Te -10°C | 3.22 | 2.96 | 2.88 | 2.83 | 3.02 | 2.72 | 3.13 | 2.97 | ||||||
| R-449A | Te -10°C | 3.22 | 2.96 | 2.88 | 2.83 | 3.02 | 2.72 | 3.13 | 2.97 | ||||||
| Parámetros a plena carga y temp. amb. 32 °C (punto A) | R-134a | Te -10°C | Capacidad de refrigeración nominal (PA) | kW | 8.21 | 10.75 | 3.80 | 2.24 | 3.48 | 4.37 | |||||
| Consumo nominal (DA) | kW | 3.74 | 4.86 | 1.61 | 1.02 | 1.68 | 1.85 | ||||||||
| COP nominal (COPA) | 2.19 | 2.21 | 2.36 | 2.19 | 2.08 | 2.36 | |||||||||
| R-407A | Te -10°C | Capacidad de refrigeración nominal (PA) | kW | 9.54 | 10.70 | 12.95 | 5.77 | 3.45 | 4.05 | 4.69 | 6.76 | 8.28 | |||
| Consumo nominal (DA) | kW | 4.65 | 5.54 | 6.24 | 2.58 | 1.62 | 2.04 | 2.44 | 2.97 | 3.93 | |||||
| COP nominal (COPA) | 2.05 | 1.93 | 2.08 | 2.24 | 2.12 | 1.99 | 1.92 | 2.28 | 2.11 | ||||||
| R-407F | Te -10°C | Capacidad de refrigeración nominal (PA) | kW | 9.59 | 12.90 | 5.73 | 3.33 | 3.94 | 4.58 | 6.75 | 8.18 | ||||
| Consumo nominal (DA) | kW | 5.03 | 6.13 | 2.91 | 1.77 | 2.15 | 2.71 | 3.21 | 4.36 | ||||||
| COP nominal (COPA) | 1.91 | 2.10 | 1.97 | 1.88 | 1.83 | 1.69 | 2.10 | 1.88 | |||||||
| Parámetros a plena carga y temp. ambiente 32 °C (punto A) | R-448A | Te -10°C | Capacidad de refrig. nominal (PA) | kW | 9.45 | 10.50 | 12.65 | 15.85 | 5.76 | 3.33 | 3.82 | 4.73 | 5.46 | 6.37 | 7.88 |
| Consumo nominal (DA) | kW | 4.83 | 5.85 | 6.23 | 8.68 | 2.83 | 1.65 | 1.98 | 2.56 | 3.09 | 3.22 | 4.43 | |||
| COP nominal (COPA) | 1.96 | 1.79 | 2.03 | 1.83 | 2.04 | 2.02 | 1.93 | 1.85 | 1.77 | 1.98 | 1.78 | ||||
| R-449A | Te -10°C | Capacidad de refrig. nominal (PA) | kW | 9.45 | 10.50 | 12.65 | 15.85 | 5.76 | 3.33 | 3.82 | 4.73 | 5.46 | 6.37 | 7.88 | |
| Consumo nominal (DA) | kW | 4.83 | 5.85 | 6.23 | 8.68 | 2.83 | 1.65 | 1.98 | 2.56 | 3.09 | 3.22 | 4.43 | |||
| COP nominal (COPA) | 1.96 | 1.79 | 2.03 | 1.83 | 2.04 | 2.02 | 1.93 | 1.85 | 1.77 | 1.98 | 1.78 | ||||
| Parámetros a plena carga y temp. amb. 25°C | R-134a | Te -10°C | COP declarado (COP2) | 2.86 | 2.62 | 2.46 | 2.90 | ||||||||
| R-407A | Te -10°C | COP declarado (COP2) | 2.55 | 2.36 | 2.26 | ||||||||||
| R-407F | Te -10°C | COP declarado (COP2) | 2.39 | 2.29 | 2.14 | ||||||||||
| Parámetros a plena carga y temp. ambiente 25°C | R-448A | Te -10°C | Consumo (D2) | kW | 1.43 | 1.76 | 2.27 | ||||||||
| COP declarado (COP2) | 2.53 | 2.32 | 2.23 | ||||||||||||
| R-449A | Te -10°C | Consumo (D2) | kW | 1.43 | 1.76 | 2.27 | |||||||||
| COP declarado (COP2) | 2.53 | 2.32 | 2.23 | ||||||||||||
| Parámetros a plena carga y temp. amb. 43 °C | R-134a | Te -10°C | COP declarado (COP3) | 1.59 | 1.60 | 1.52 | |||||||||
| Parámetros a plena carga y temp. ambiente 43°C | R-448A | Te -10°C | COP declarado (COP3) | 1.42 | 1.32 | 1.41 | 1.31 | 1.36 | 1.31 | 1.26 | 1.36 | 1.24 | |||
| R-449A | Te -10°C | COP declarado (COP3) | 1.42 | 1.32 | 1.41 | 1.31 | 1.36 | 1.31 | 1.26 | 1.36 | 1.24 | ||||
| Ventilador | Tipo | Axial | Axial | Axial | Axial | Axial | Axial | Axial | Axial | Axial | Axial | Axial | |||
| Dimensiones | Unidad | Altura | mm | 872 | 872 | 1727 | 1727 | 872 | 662 | 662 | 662 | 662 | 872 | 872 | |
| Anchura | mm | 1353 | 1353 | 1348 | 1348 | 1353 | 1101 | 1101 | 1101 | 1101 | 1353 | 1353 | |||
| Profundidad | mm | 575 | 575 | 612 | 612 | 575 | 444 | 444 | 444 | 444 | 575 | 575 | |||
| Peso | Unidad | kg | 125 | 126 | 204 | 226 | 112 | 69.7 | 71.7 | 73.7 | 73.7 | 119 | 123 | ||
| Refrigerante | Tipo | R-134a | R-134a | R-134a | R-134a | R-134a | R-134a | ||||||||
| Carcasa | Color | Gris claro | Gris claro | Gris claro | Gris claro | Gris claro | Gris claro | Gris claro | Gris claro | Gris claro | Gris claro | Gris claro | |||
| Refrigerante | GWP | 1430 | 1430 | 1430 | 1430 | 1430 | 1430 | ||||||||
| Tipo 2 | R-407A | R-407A | R-407A | R-407A | R-407A | R-407A | R-407A | R-407A | R-407A | ||||||
| Tipo 4 | R-407H | R-407H | R-407H | R-407H | R-407H | R-407H | R-407H | R-407H | |||||||
| Tipo 3 | R-407F | R-407F | R-407F | R-407F | R-407F | R-407F | R-407F | R-407F | |||||||
| Tipo 5 | R-448A | R-448A | R-448A | R-448A | R-448A | R-448A | R-448A | R-448A | R-448A | R-448A | R-448A | ||||
| GWP Tipo 5 | 1387 | 1387 | 1387 | 1387 | 1387 | 1387 | 1387 | 1387 | 1387 | 1387 | 1387 | ||||
| GWP Tipo 2 | 2107 | 2107 | 2107 | 2107 | 2107 | 2107 | 2107 | 2107 | 2107 | ||||||
| GWP Tipo 3 | 1825 | 1825 | 1825 | 1825 | 1825 | 1825 | 1825 | 1825 | |||||||
| GWP Tipo 4 | 1495 | 1495 | 1495 | 1495 | 1495 | 1495 | 1495 | 1495 | |||||||
| Alimentación eléctrica | Fase | 3~ | 3~ | 3~ | 3~ | 3~ | 3~ | 3~ | 3~ | 3~ | 3~ | 3~ | |||
| Frecuencia | Hz | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | |||
| Tensión | V | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | |||
| Notas | (1) - SRG 20°C, Ta=32°C, Te=-35°C | (1) - SRG 20°C, Ta=32°C, Te=-35°C | (1) - SRG 20°C, Ta=32°C, Te=-35°C | (1) - SRG 20°C, Ta=32°C, Te=-35°C | (1) - SRG 20°C, Ta=32°C, Te=-35°C | (1) - SRG 20°C, Ta=32°C, Te=-35°C | (1) - SRG 20°C, Ta=32°C, Te=-35°C | (1) - SRG 20°C, Ta=32°C, Te=-35°C | (1) - Consulte la condición: Temperatura ambiente exterior = 32°C, Temperatura de evaporación = -10°C y sobrecalentamiento a 10K (aplicaciones de temperatura media) | (1) - SRG 20°C, Ta=32°C, Te=-35°C | (1) - SRG 20°C, Ta=32°C, Te=-35°C | ||||
| (2) - El nivel de presión sonora se mide en una cámara anecoica a 10 m | (2) - El nivel de presión sonora se mide en una cámara anecoica a 10 m | (2) - El nivel de presión sonora se mide en una cámara anecoica a 10 m | (2) - El nivel de presión sonora se mide en una cámara anecoica a 10 m | (2) - El nivel de presión sonora se mide en una cámara anecoica a 10 m | (2) - El nivel de presión sonora se mide en una cámara anecoica a 10 m | (2) - El nivel de presión sonora se mide en una cámara anecoica a 10 m | (2) - El nivel de presión sonora se mide en una cámara anecoica a 10 m | (2) - El nivel de presión sonora se mide en una cámara anecoica a 10 m | (2) - El nivel de presión sonora se mide en una cámara anecoica a 10 m | (2) - El nivel de presión sonora se mide en una cámara anecoica a 10 m | |||||
| (3) - Su funcionamiento se basa en gases fluorados de efecto invernadero | (3) - Su funcionamiento se basa en gases fluorados de efecto invernadero | (3) - Su funcionamiento se basa en gases fluorados de efecto invernadero | (3) - Su funcionamiento se basa en gases fluorados de efecto invernadero | (3) - Su funcionamiento se basa en gases fluorados de efecto invernadero | (3) - Su funcionamiento se basa en gases fluorados de efecto invernadero | (3) - Su funcionamiento se basa en gases fluorados de efecto invernadero | (3) - Su funcionamiento se basa en gases fluorados de efecto invernadero | (3) - Su funcionamiento se basa en gases fluorados de efecto invernadero | (3) - Su funcionamiento se basa en gases fluorados de efecto invernadero | (3) - Su funcionamiento se basa en gases fluorados de efecto invernadero | |||||
| (4) - Datos publicados según la condición: temperatura del gas de retorno 20°C, excepto para R-407H | (4) - Datos publicados según la condición: temperatura del gas de retorno 20°C, excepto para R-407H | (4) - Datos publicados según la condición: temperatura del gas de retorno 20°C, excepto para R-407H | (4) - Datos publicados según la condición: temperatura del gas de retorno 20°C, excepto para R-407H | (4) - Datos publicados según la condición: temperatura del gas de retorno 20°C, excepto para R-407H | (4) - Datos publicados según la condición: temperatura del gas de retorno 20°C, excepto para R-407H | (4) - Datos publicados según la condición: temperatura del gas de retorno 20°C, excepto para R-407H | (4) - Datos publicados según la condición: temperatura del gas de retorno 20°C, excepto para R-407H | ||||||||
| (5) - Datos publicados según la condición: SH10K para R-407H | (5) - Datos publicados según la condición: SH10K para R-407H | (5) - Datos publicados según la condición: SH10K para R-407H | (5) - Datos publicados según la condición: SH10K para R-407H | (5) - Datos publicados según la condición: SH10K para R-407H | (5) - Datos publicados según la condición: SH10K para R-407H | (5) - Datos publicados según la condición: SH10K para R-407H | (5) - Datos publicados según la condición: SH10K para R-407H | ||||||||