Tabla de especificaciones técnicas LREN-A / LRNUN-AY1

LREN12AY1B / LRNUN5AY1
Capacidad de refrigeración Temperatura media kW kW 31.7 (4)
  Temperatura baja kW kW 17.3 (3)
Consumo Temperatura media Nom. kW 20.1 (4)
  Temperatura baja Nom. kW 18.6 (3)
COP Temperatura media Nom.   1.58 (4)
  Temperatura baja Nom.   0.93 (3)
Notas (1) - Minimum load of each individual refrigeration indoor unit: 3 KW (for Medium Temperature Operation)
  (2) - Minimum load of each individual refrigeration indoor unit: 2 KW (for Low Temperature Operation).
  (3) - Condiciones nominales: temperatura de saturación equivalente a la presión de aspiración: -35 °C (LT), temp. exterior 32 °C, aspiración SH 10K.
  (4) - Rated conditions: saturation temperature equivalent to suction pressure: -10°C (MT), outdoor temp. 32°C, Suction SH 10K
  (5) - Sound pressure data: measured at 1m in front of unit, at 1.5m height. Nominal operation condition – Medium evaporation temperature (MT)
  (6) - For MT (Medium Temperature) Operation
  (7) - For LT (Low Temperature) Operation