FDXS25F2VEB / RXS25L3V1B FDXS35F2VEB / RXS35L3V1B
Poff (modo apagado) W 14.0 14.0
Refrigeración Psb (refrigeración en modo de espera) W 14.0 14.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25
Eficiencia estacional (conforme a EN14825) Refrigeración Pdesign kW 2.40 3.40
    Consumo energético anual kWh 149 228
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 5.63 5.21
    Condición D (20 ℃ - 27/19) Pdc kW 1.33 1.46
      consumo kW 0.12 0.15
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 10.66 9.80
    Condición C (25 ℃ - 27/19) consumo kW 0.15 0.23
      Pdc kW 1.27 1.61
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 8.43 7.02
    Condición A (35 °C - 27/19) consumo kW 0.64 1.15
      Pdc kW 2.40 3.40
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.74 2.96
    Condición B (30 ℃ - 27/19) Pdc kW 1.76 2.50
      consumo kW 0.30 0.53
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 5.89 4.68
  Calefacción (clima medio) Consumo energético anual kWh 858 1,047
    Pdesign kW 2.60 2.90
    Cap. calefacción reserva necesaria condiciones diseño kW 0.44 0.48
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scopnet a A+ A
    TBivalent Pdh (capacidad de calefacción declarada) kW 2.30 2.57
      Consumo kW 0.92 1.10
      Tbiv (temperatura bivalente) °C -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.51 2.33
    Condición C (7 ℃) Pdh (cap. de calefacción decl.) kW 1.00 1.02
      Consumo kW 0.18 0.21
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 5.50 4.80
    TOL Tol (límite de funcionamiento de temp.) °C -15 -15
      Pdh (capacidad de calefacción declarada) kW 1.93 2.15
      Consumo kW 0.91 1.12
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 2.13 1.92
    Condición A (-7℃) Pdh (cap. de calefacción decl.) kW 2.30 2.57
      Consumo kW 0.92 1.10
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.51 2.33
    Condición D (12 ℃) Pdh (cap. de calefacción decl.) kW 1.17 1.19
      Consumo kW 0.17 0.19
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 6.95 6.26
    Condición B (2 ℃) Consumo kW 0.32 0.39
      Pdh (cap. de calefacción decl.) kW 1.40 1.57
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.39 4.02
Capacidad de refrigeración Nom. Btu/h 8,150 (2) 11,500 (2)
  Mín. kW 1.3 1.4
  Nom. kcal/h 2,060 (2) 2,920 (2)
  Máx. kW 3.0 3.8
  Mín. kcal/h 1,110 1,200
  Mín. Btu/h 4,400 4,800
  Nom. kW 2.4 (2) 3.4 (2)
  Máx. Btu/h 10,200 13,000
  Máx. kcal/h 2,580 3,260
Pck (modo de calentador del cárter) W 0.0 0.0
Eficiencia nominal Consumo energético anual kWh 321 (0.000) 574 (0.000)
  Directiva de etiquetado de eficiencia energética Calefacción A B
  Nominal efficiency-=-Cop 3.74 (1) 2.96 (1)
Calefacción Heating-=-Heating cdh degradation heating 0.25 0.25
Conexiones de tubería Líquido D.E. mm 6.35 6.35
  Gas D.E. mm 9.5 9.5
  Drenaje D.E. mm VP20 (Diá. ext. 26, diá. int. 20) VP20 (Diá. ext. 26, diá. int. 20)
  Aislamiento térmico Tubos de líquido y de gas Tubos de líquido y de gas
Capacidad de calefacción Mín. Btu/h 4,400 4,800
  Nom. Btu/h 10,900 (2) 13,600 (2)
  Máx. kcal/h 3,870 4,300
  Máx. Btu/h 15,350 17,100
  Nom. kW 3.2 (2) 4.0 (2)
  Mín. kW 1.3 1.4
  Nom. kcal/h 2,750 (2) 3,440 (2)
  Mín. kcal/h 1,110 1,200
  Máx. kW 4.5 5.0
Pto (Thermostat off) W 7.0 7.0
Consumo Refrigeración Nom. kW 0.641 (2) 1.148 (2)
  Calefacción Nom. kW 0.800 (2) 1.150 (2)
Unidad interior Sí Sí
Corriente Corriente nominal de funcionamiento (50 Hz) Calefacción A 4.20 5.40
    Refrigeración A 3.85 5.31
Notas EER/COP conforme a Eurovent 2012, solo para uso fuera de la UE EER/COP conforme a Eurovent 2012, solo para uso fuera de la UE
  Eficiencia nominal: refrigeración a 35°/27° de carga nominal, calefacción a 7°/20° de carga nominal Eficiencia nominal: refrigeración a 35°/27° de carga nominal, calefacción a 7°/20° de carga nominal